Mechanical properties improvement of pre-deformed Al–Zn–Mg–Cu alloys by electroshocking treatment based on the non-equilibrium scattering of electron-dislocation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 15 publications
(3 citation statements)
references
References 28 publications
0
3
0
Order By: Relevance
“…Before EST, the values of mapping strain were ranged from −0.13 to 0.08. After EST, the values of strain were ranged from −0.05 to 0.05, which indicates the distribution of micro-strain become uniform.Previous studies have shown that the migration of dislocations could be promoted by EST, thus decrease the density of dislocations and lead the dislocations to pile up at the grain boundaries [17,18]. The decrease of lattice distortion can be attributed to the fact that EST activated the movement of dislocations and reduced dislocation entanglement, so as to make the micro-strain distribution more uniform.…”
Section: Resultsmentioning
confidence: 99%
“…Before EST, the values of mapping strain were ranged from −0.13 to 0.08. After EST, the values of strain were ranged from −0.05 to 0.05, which indicates the distribution of micro-strain become uniform.Previous studies have shown that the migration of dislocations could be promoted by EST, thus decrease the density of dislocations and lead the dislocations to pile up at the grain boundaries [17,18]. The decrease of lattice distortion can be attributed to the fact that EST activated the movement of dislocations and reduced dislocation entanglement, so as to make the micro-strain distribution more uniform.…”
Section: Resultsmentioning
confidence: 99%
“…More interestingly, inverse Fourier transform images of different orientations could clearly be seen in Figure 4 , suggesting crystal distortions in the 0.9P-CNT sample. Specifically, the red symbol T in the figure indicates the defects present in the sample [ 42 ], and many symbols of T revealed that the as-prepared sample possessed a large number of surface defects.…”
Section: Resultsmentioning
confidence: 99%
“…The experimental procedure is shown in figure 2(a). It should be noted that the so-called electroshock treatment (EST) is a bit different from common EPT [23]. The current used in the EST has the characteristics of ultra-low frequency unidirectional positive pulse and very limited energy density (figure 2(b)), to minimize the temperature rise and effectively weaken the thermal effect by the current impact.…”
Section: Electroshock Assisted Uniaxial Tensile Testmentioning