Measurements of steady flow through a bileaflet mechanical heart valve using stereoscopic PIV

Abstract: Computational modeling of bileaflet heart valve (BiMHV) flow requires experimentally validated datasets and improved knowledge of BiMHV fluid mechanics. In this study, flow was studied downstream of a model BiMHV in an axisymmetric aortic sinus using stereoscopic particle image velocimetry. The inlet flow was steady and the Reynolds number based on the aortic diameter was 7600. Results showed the outof-plane velocity was of similar magnitude as the transverse velocity. Although additional studies are needed fo… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
9
0

Year Published

2012
2012
2019
2019

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 13 publications
(9 citation statements)
references
References 30 publications
0
9
0
Order By: Relevance
“…From the plot, it can be seen that the peak velocity just past the leaflets increased from around 1.2 m/s for the functioning valve to 2.1 m/s for the malfunctioning valve. This is expected because closing one of the leaflets (the leaflet in the negative y-axis) means more fluid is forced The velocity profiles just past the leaflet tips (at 414 mm downstream of the inlet) using the Hutchinson et al run settings and fluid [60] are compared for the two valves in Figure 8. This point was chosen because it was the location of the velocity data available from Blackmore et al [59] for comparison.…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations
“…From the plot, it can be seen that the peak velocity just past the leaflets increased from around 1.2 m/s for the functioning valve to 2.1 m/s for the malfunctioning valve. This is expected because closing one of the leaflets (the leaflet in the negative y-axis) means more fluid is forced The velocity profiles just past the leaflet tips (at 414 mm downstream of the inlet) using the Hutchinson et al run settings and fluid [60] are compared for the two valves in Figure 8. This point was chosen because it was the location of the velocity data available from Blackmore et al [59] for comparison.…”
Section: Resultsmentioning
confidence: 99%
“…In this work a CFD-based, three-dimensional model of a bileaflet artificial heart valve was created in both a functioning and malfunctioning position. The results of simulations were compared with literature [57,59,60] to evaluate the accuracy of the various computational methods. Velocity profiles and contours were also compared between the two valves.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…Some hemodynamic differences between different valve types are well known since commercial valve prostheses are normally evaluated in vitro according to ISO 5840. Furthermore, hemodynamics of different valve types were investigated in a number of studies . These in vitro and in silico studies were, however, usually done with the prostheses being mounted in a straight pipe and/or generic geometry of the aorta.…”
mentioning