2018
DOI: 10.1016/j.fuproc.2018.06.016
|View full text |Cite
|
Sign up to set email alerts
|

Measurements of particulate matter concentration by the light scattering method: Optimization of the detection angle

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
25
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 43 publications
(25 citation statements)
references
References 30 publications
0
25
0
Order By: Relevance
“…The relationship between polydisperse particle mass concentration and the light scattering intensity of a fixed angle is described in Equation (6) according to theory by Hulst, V.D. [35] and the former study of Chen et al [23]. The normalized particle mass size distribution f m ( D ) is described in Equation (7).…”
Section: Methods and Calculationsmentioning
confidence: 99%
See 1 more Smart Citation
“…The relationship between polydisperse particle mass concentration and the light scattering intensity of a fixed angle is described in Equation (6) according to theory by Hulst, V.D. [35] and the former study of Chen et al [23]. The normalized particle mass size distribution f m ( D ) is described in Equation (7).…”
Section: Methods and Calculationsmentioning
confidence: 99%
“…In addition, Görner [22] calculated the scattering light of 1 mg/m 3 particles with different particle size and found the light intensity of submicron particles could be an order of magnitude higher than micron particles. Later, Chen et al [23] experimentally demonstrated the sensitivity of mass concentration changes with particle size at any detection angle. In coal-fired power plants, the size of particles varies with time due to the coal type, combustion condition, boiler load, and precipitator performance [6,24,25].…”
Section: Introductionmentioning
confidence: 99%
“…The light scattering method is a high resolution and accurate, non-invasive method with a wide array of possible applications, especially at low concentrations. Regarding the use of this method in power plants, particle refractive index, density and shape have to be taken into account [10].…”
Section: Abstract -mentioning
confidence: 99%
“…The light scattering method is a high resolution and accurate, non-invasive method with a wide array of possible applications, especially at low concentrations. Regarding the use of this method in power plants, particle refractive index, density and shape have to be taken into account [10].The study of Peng et al studied particle size distribution in different humidity conditions using ELPI (Electrical Low Pressure Impactor). Increased humidity causes increase in total concentration of PM, as shown by results.…”
mentioning
confidence: 99%
“…In recent years, the monitoring of air pollution has been heavily focused on particulate matter (PM) [1,2]. The negative impact of fine and ultra-fine particles has been studied by many authors.…”
Section: Introductionmentioning
confidence: 99%