Measurements of Cavity Ringdown Spectroscopy of Acetone in the Ultraviolet and Near-Infrared Spectral Regions: Potential for Development of a Breath Analyzer

Abstract: We report a study on the cavity ringdown spectroscopy of acetone in both the ultraviolet (UV) and the near-infrared (NIR) spectral regions to explore the potential for development of a breath analyzer for disease diagnostics. The ringdown spectrum of acetone in the UV (282.4-285.0 nm) region is recorded and the spectrum is in good agreement with those obtained by other spectral techniques reported in the literature. The absorption cross-section of the C-H stretching overtone of acetone in the NIR (1632.7-1672.… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
62
0
1

Year Published

2008
2008
2015
2015

Publication Types

Select...
4
3

Relationship

2
5

Authors

Journals

citations
Cited by 47 publications
(64 citation statements)
references
References 35 publications
(33 reference statements)
1
62
0
1
Order By: Relevance
“…This measurement is in good agreement with that of Wang et al (2004) [28] who report 1.2 × 10 -21 cm 2 at 6000 cm -1 . The peak isoprene cross section is higher reaching a maximum of 3.6 ± 0.2 × 10 -21 cm 2 at 1624.7 nm (6155 cm -1 ).…”
Section: Resultssupporting
confidence: 92%
“…This measurement is in good agreement with that of Wang et al (2004) [28] who report 1.2 × 10 -21 cm 2 at 6000 cm -1 . The peak isoprene cross section is higher reaching a maximum of 3.6 ± 0.2 × 10 -21 cm 2 at 1624.7 nm (6155 cm -1 ).…”
Section: Resultssupporting
confidence: 92%
“…[43][44][45][46] In this method, absorbance of the atmosphere is used as the background baseline. τ atm , τ 0 , and τ breath are the ringdown times when the gas cell is filled with the laboratory atmosphere to 1 atm, the cell is vacuumed, and the cell is filled with a breath gas to 1 atm, respectively.…”
Section: Data Processing Algorithm and Methodsmentioning
confidence: 99%
“…For example, in our previous report, a compact atmospheric ringdown cavity with a cavity length of 10 cm was constructed and implemented to explore the potential instrument portability (optical configuration and detection sensitivity). 44 That device was not integrated with electronics, a light source, a detector, pressure control, and sample introduction. The detection limit of the system was only 1.5 ppm due to the short cavity length.…”
Section: Advantages and Limitation Of The Breath Analyzer Comparedmentioning
confidence: 99%
See 2 more Smart Citations