1981
DOI: 10.1016/0191-278x(81)90025-1
|View full text |Cite
|
Sign up to set email alerts
|

Measurement of the spontaneous-fission disintegration constant of 238U

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
1
0
5

Year Published

1981
1981
2021
2021

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 16 publications
(7 citation statements)
references
References 13 publications
1
1
0
5
Order By: Relevance
“…The value of λ F utilized was of (8.50 ± 0.17) X 10 -17 a -1 (Holden, & Hoffman, 2000), which is the recommended value by IUPAC (International Union of Pure and Applied Chemistry). This value is in agreement with those determined through the fission track procedure (Hadler et al, 1981(Hadler et al, , 2003Guedes et al 2003a,b;Yoshioka et al, 2005).…”
Section: Edm Dating In Zirconsupporting
confidence: 86%
“…The value of λ F utilized was of (8.50 ± 0.17) X 10 -17 a -1 (Holden, & Hoffman, 2000), which is the recommended value by IUPAC (International Union of Pure and Applied Chemistry). This value is in agreement with those determined through the fission track procedure (Hadler et al, 1981(Hadler et al, , 2003Guedes et al 2003a,b;Yoshioka et al, 2005).…”
Section: Edm Dating In Zirconsupporting
confidence: 86%
“…1). Os únicos trabalhos realizados para a determinação da constante de fissão espontânea λ f a partir de estudos de traços de fissão foram aqueles desenvolvidos por Hadler et al (1981) e Guedes et al (2000), cujos valores obtidos se estabeleceram em 8,6x10 -17 anos e 8,35x10 -17 anos, respectivamente. Observa-se que estes valores são muito próximos do valor de consenso admitido pela comunidade científica atualmente que é de 8,5x10 -17 anos.…”
Section: Fissão Nuclear E Geocronologiaunclassified
“…Thermal neutron fluence can be accurately measured by either metal-activation monitors (Van den haute et al 1988;de Corte et al 1991de Corte et al , 1995Enkelmann et al 2005;Curvo et al 2013) or standard glasses calibrated through uranium thin films Soares et al 2014a). The 238 U spontaneous fission decay constant was accurately determined by measurements of etched tracks in solid-state detectors (Hadler et al 1981;Guedes et al 2000Guedes et al , 2002Guedes et al , 2003aYoshioka et al 2005). Detection efficiencies for fission-track revelation and observation were extensively studied by the distribution of projected lengths of etched fission tracks (Jonckheere and Van den haute 1998Jonckheere 2003).…”
Section: Introductionmentioning
confidence: 99%