2007
DOI: 10.1007/s00542-007-0440-z
|View full text |Cite
|
Sign up to set email alerts
|

Measurement of the pressure broadening coefficients of the oxygen A-band using a low cost, polarization stabilized, widely tunable vertical-cavity surface-emitting laser

Abstract: Vertical-cavity surface-emitting lasers (VCSELs) are used for oxygen monitoring via tunable diode laser spectroscopy at 760 nm wavelength. For the desired application, novel polarization-stable laser diodes based on AlGaAs were developed. We present measurements of the pressure-broadening coefficients of the electric dipole forbidden oxygen A-band b(exp 1) Sigma+(exp 9) --> X(exp 3) Sigma+(exp 9) transition at 760 nm. The time the pressure-broadening coefficients were determined with a temperature tuned VCSEL.… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
7
0

Year Published

2008
2008
2012
2012

Publication Types

Select...
2
2
2

Relationship

3
3

Authors

Journals

citations
Cited by 7 publications
(7 citation statements)
references
References 17 publications
0
7
0
Order By: Relevance
“…At this wavelength, the O 2 absorption spectrum is minimally sensitive towards temperature changes and it is fairly influenced by the pressure variation [17,11,13]. The lowest oxygen concentration that can be measured is about 20-50 ppm which corresponds to transmission change of about 0.0005 [11]. The smallest experimentally detected absorption is about 3 times larger than the shot noise limit and is about 10 −6 .…”
Section: Application To Oxygen Detectionmentioning
confidence: 93%
See 2 more Smart Citations
“…At this wavelength, the O 2 absorption spectrum is minimally sensitive towards temperature changes and it is fairly influenced by the pressure variation [17,11,13]. The lowest oxygen concentration that can be measured is about 20-50 ppm which corresponds to transmission change of about 0.0005 [11]. The smallest experimentally detected absorption is about 3 times larger than the shot noise limit and is about 10 −6 .…”
Section: Application To Oxygen Detectionmentioning
confidence: 93%
“…Typically, the absorption of oxygen in ambient air at the 760 nm line is of the order 2.6% with an optical path length of around 1 m [13]. At this wavelength, the O 2 absorption spectrum is minimally sensitive towards temperature changes and it is fairly influenced by the pressure variation [17,11,13]. The lowest oxygen concentration that can be measured is about 20-50 ppm which corresponds to transmission change of about 0.0005 [11].…”
Section: Application To Oxygen Detectionmentioning
confidence: 99%
See 1 more Smart Citation
“…Owing to their convenient, mode-hop-free tunability via the operating current, high modulation bandwidths, and sufficiently low linewidths, single-mode VCSELs are good candidates for nonlinear spectroscopy [98] (and its use in optical interrogation for atomic sensors like clocks [91,99] or magnetometers [100]) or gas sensing, with oxygen sensors operating in the 760 nm wavelength region as a prominent example [101][102][103]. Gas sensing with long-wavelength VCSELs is discussed in Chap.…”
Section: Emission Linewidthmentioning
confidence: 99%
“…3 The strength of the broadening effect depends on different properties of the collision partners. The effect of pressure broadening depends therefore on the gas mixture and can only be calculated with the knowledge of the volume mixing ratio of all components contained in the analyzed gas mixture:…”
Section: Gas Concentration Measurements Based On Absorption Spectroscopymentioning
confidence: 99%