Measurement of neutron dose equivalent outside and inside of the treatment vault of GRID therapy

Abstract: This work indicates that there is no significant change of the Hn,D and HG in GRID therapy, compared with a conventional external beam therapy. However, the neutron and scattered photon dose equivalent to the patient decrease dramatically with the grid and can be clinical irrelevant. Meanwhile, the users of a grid should be aware of the possible high dose to the radiation worker from the radiation activation on the surface of the grid. A delay in handling the grid after the beam delivery is suggested.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
14
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(15 citation statements)
references
References 24 publications
(34 reference statements)
1
14
0
Order By: Relevance
“… Measurements of neutron absorbed dose and neutron dose equivalent at proton therapy beam lines were executed. First, measurements on passive beam lines were undertaken by Binns and Hough ( 8 ) and Yan et al ( 9 ) and for active beam lines by Schneider et al ( 10 ). Since then, a large number of neutron dose measurements were reported including several beam lines, in patient measurements, as well as measurements in treatment rooms, including a variety of dosimeters and set-ups including neutron energy spectra measurements.…”
Section: Introductionmentioning
confidence: 99%
“… Measurements of neutron absorbed dose and neutron dose equivalent at proton therapy beam lines were executed. First, measurements on passive beam lines were undertaken by Binns and Hough ( 8 ) and Yan et al ( 9 ) and for active beam lines by Schneider et al ( 10 ). Since then, a large number of neutron dose measurements were reported including several beam lines, in patient measurements, as well as measurements in treatment rooms, including a variety of dosimeters and set-ups including neutron energy spectra measurements.…”
Section: Introductionmentioning
confidence: 99%
“…20 Regarding the brass grid block, however, neutron dose and radiation activation are concerns for high energy beams. 21 A unique hybrid collimation system for megavoltage grid therapy was proposed that uses two perpendicular sets of equally spaced rectangular openings, with one set defined by the MLC and the other by Cerrobend bars. While this orthogonal grid pattern results in more efficient delivery, 22 it is still difficult to customize grid patterns.…”
Section: Introductionmentioning
confidence: 99%
“…This seems in contrast with Wang et al . 's results,[ 23 ] who showed that the GRID reduced the dose equivalent of thermal neutrons 39.3% (at the IC). The reason for this disagreement could be this point that our calculations were done in the air while their dosimeter was attached to the left buccal side of the RANDO ® phantom.…”
Section: Discussionmentioning
confidence: 99%
“…'s study. [ 23 ] The genus of the GRID is brass (63% copper and 37% zinc) and has a thickness of 7.62 cm. The conical holes of this GRID follow direction of radiation divergence.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation