1995
DOI: 10.1021/ac00117a006
|View full text |Cite
|
Sign up to set email alerts
|

Measurement of Gases by a Suppressed Conductometric Capillary Electrophoresis Separation System

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
25
0

Year Published

1998
1998
2013
2013

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 60 publications
(25 citation statements)
references
References 0 publications
0
25
0
Order By: Relevance
“…Although sample concentration by three orders has been reported [3], it seems that eventually the volume around the column head will be depleted from the analytes and therefore HC-FASS also has its limitations. Indicators of such behavior were observed by Zhang and Thomann [4] and Dasgupta and Klar [5]. From the discussion above it follows quite obviously that a continuous fresh supply of the sample could increase the HC-FASS detection sensitivity even more.…”
Section: Introductionmentioning
confidence: 77%
“…Although sample concentration by three orders has been reported [3], it seems that eventually the volume around the column head will be depleted from the analytes and therefore HC-FASS also has its limitations. Indicators of such behavior were observed by Zhang and Thomann [4] and Dasgupta and Klar [5]. From the discussion above it follows quite obviously that a continuous fresh supply of the sample could increase the HC-FASS detection sensitivity even more.…”
Section: Introductionmentioning
confidence: 77%
“…The CE systems with suppressed conductivity detection have been developed, e.g. for determination of soluble ionogenic atmospheric gases [198]. Detailed studies were also carried out on the effect of variation in separation potential, hydrostatic pressure and using auxiliary electroosmotic pumping on CE with suppressed conductivity detection [199].…”
Section: Conductivity Detection In Capillary Electrophoresismentioning
confidence: 99%
“…Bodor et al [49] have used a measuring cell based on a drilled cross in a Perspex-block and the electrical contact to the column effluent is made via a bridging electrolyte solution. In an effort to achieve lower detection limits, suppressed conductivity detection, as known from ion-chromatography, has also been adapted for capillary electrophoresis [50][51][52][53][54][55]. Good detection limits in the order of 10 27 M have been achieved, however, the implementation is not easy because of the small dimensions involved and the approach has not been widely adopted.…”
Section: Conductimetric Detectionmentioning
confidence: 99%