1989
DOI: 10.1161/01.cir.80.4.1016
|View full text |Cite
|
Sign up to set email alerts
|

Measurement of end-systolic pressure-volume relations by intra-aortic balloon occlusion.

Abstract: (Circulation 1989;80:1016-1028

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
10
0

Year Published

1990
1990
2013
2013

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 15 publications
(10 citation statements)
references
References 60 publications
0
10
0
Order By: Relevance
“…From the linear ESPVR, two descriptors were calculated; the slope, or E e " and the V14. VI4 was used rather than Vd because the ESPVR has been demonstrated to be nonlinear to some extent in many preparations (24)(25)(26)(27)(28). Thus, extrapolation beyond the range of measurement is undesirable.…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations
“…From the linear ESPVR, two descriptors were calculated; the slope, or E e " and the V14. VI4 was used rather than Vd because the ESPVR has been demonstrated to be nonlinear to some extent in many preparations (24)(25)(26)(27)(28). Thus, extrapolation beyond the range of measurement is undesirable.…”
Section: Methodsmentioning
confidence: 99%
“…PV loops have been analyzed by a variety of techniques (13,14,35,(44)(45)(46), but most commonly by generating ESPVR, to assess ventricular function in control conditions and in response to various hemodynamic perturbations. There have, however, been several concerns about the ESPVR, including those of nonlinearity both outside and within the range of measurement (24)(25)(26)(27)(28), load dependency, particularly related to the technique of generating the relationship itself (13,IS,23,29), and relative insensitivity to changes in contractility (43). We have recently performed studies validating the accuracy of the conductance catheter in the in situ newborn heart (37), and undertook the present study to critically analyze the ESPVR in the newborn.…”
Section: Parallel Conductance Versus Esv and Edvmentioning
confidence: 97%
See 2 more Smart Citations
“…19 A custom-made 50-mL intra-aortic balloon (Datascope, Inc) was placed during fluoroscopy in the aortic root from the femoral artery and was connected to a System 90-T intra-aortic balloon pump (Datascope Inc). The balloon was triggered to inflate during diastole and to remain inflated during the following contraction.…”
Section: End-systolic Elastancementioning
confidence: 99%