2007
DOI: 10.1109/lmwc.2007.895742
|View full text |Cite
|
Sign up to set email alerts
|

Measurement Method for Imbalance Factors in Direct-Conversion Quadrature Radar Systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
15
0

Year Published

2010
2010
2023
2023

Publication Types

Select...
4
3
1

Relationship

0
8

Authors

Journals

citations
Cited by 29 publications
(15 citation statements)
references
References 8 publications
0
15
0
Order By: Relevance
“…In addition to the DC-offset and , the amplitude and the phase errors and between the channels should be estimated [16]. This was performed by using a wall plate of an automatic miller machine as a radar target, which can be programmed to move accurately to the desired position with a desired velocity.…”
Section: A Correction Of Amplitude and Phase Imbalancesmentioning
confidence: 99%
“…In addition to the DC-offset and , the amplitude and the phase errors and between the channels should be estimated [16]. This was performed by using a wall plate of an automatic miller machine as a radar target, which can be programmed to move accurately to the desired position with a desired velocity.…”
Section: A Correction Of Amplitude and Phase Imbalancesmentioning
confidence: 99%
“…These are the amplitude and the phase imbalance that exist between the I and Q channels [10], [11]. Thus, the baseband signals become (3) Now in the IQ plane, the data does not form an arc of the circle, but an arc of an ellipse instead.…”
Section: Microwave Doppler Monitoring Of Heartmentioning
confidence: 99%
“…Whereas in the aforementioned applications, the accuracy of the displacement measurement, particularly changes in the breathing amplitude, are very important features. However, real radar components suffer from problems with amplitude and phase imbalance due to hardware imperfections [10], [11]. To ensure accurate displacement calculation and signal interpretation, the imbalances need to be accurately measured and compensated for.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…In addition, there are applications where obtrusive contact electrodes could disturb the measurement itself such as sleep quality monitoring in a medical sleep laboratory. The current challenges with radar monitoring, however, include removal of motion and respiration artifacts of the patient [1,2] and the background, development of a non-linear channel combining algorithm [3,4], estimation of amplitude and phase imbalance of the two radar channels [5], and development of rate detection methods [6][7][8]. Rate detection should be robust for the changes in the signal waveform due to the measurement position.…”
Section: Introductionmentioning
confidence: 99%