2018
DOI: 10.1016/j.measurement.2018.01.056
|View full text |Cite
|
Sign up to set email alerts
|

Measurement, evaluation and proposed solution for power distribution arrangements with electrical cables in parallel

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(3 citation statements)
references
References 31 publications
0
3
0
Order By: Relevance
“…Second, computational fluid dynamic (CFD) and finite element methods (FEM) can also be used to study this thermal balance and to recreate different types of conductors and operation and weather conditions [ 13 , 14 ] and finally, direct or indirect measurement methods of some line parameters can be used to estimate the temperature of the conductor [ 15 , 16 , 17 ]. All the previous methods were used to check the reliability of the infrared thermometer measurements.…”
Section: Methodsmentioning
confidence: 99%
“…Second, computational fluid dynamic (CFD) and finite element methods (FEM) can also be used to study this thermal balance and to recreate different types of conductors and operation and weather conditions [ 13 , 14 ] and finally, direct or indirect measurement methods of some line parameters can be used to estimate the temperature of the conductor [ 15 , 16 , 17 ]. All the previous methods were used to check the reliability of the infrared thermometer measurements.…”
Section: Methodsmentioning
confidence: 99%
“…where z H is the smoke layer height measured from smoke layer border to ceiling (m), H is the fire compartment height (m), α is the fire growth coefficient (kW/s 2 )-for this scenario it is 0.003 kW/s 2 , A is the fire compartment area (m 2 ), n is coefficient of fire type (-)-for t-quadratic fire it is 2 and t is time after time ignition (s). Equation (6) proves that smoke volume is not a material parameter, but is determined by geometry of the fire compartment. Material parameter is extinction area of smoke.…”
Section: Application To Selected Fire Scenariomentioning
confidence: 99%
“…A more complex process used to calculate the local volumetric Joule heating is described in the scientific paper [3]. The influence of the electrical current and the environment on the electrical cable temperature has been studied in detail in scientific papers [4][5][6].…”
Section: Introductionmentioning
confidence: 99%