1988
DOI: 10.1016/0021-9614(88)90092-4
|View full text |Cite
|
Sign up to set email alerts
|

Measurement and correlation of the (pressure, density, temperature) relation of methane in the temperature range from 273.15 K to 323.15 K at pressures up to 8 MPa

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

7
18
0

Year Published

1988
1988
2020
2020

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 59 publications
(25 citation statements)
references
References 14 publications
7
18
0
Order By: Relevance
“…at T ≈ 240 K, the measuring runs of Goodwin (27) and Vennix et al (25) show systematic deviations from the new measurements of up to 2 · 10 −3 · ρ; the uncertainties of these values are given in table 1. In the overlapping temperature range between 240 K and 323 K at pressures p 12 MPa, an excellent agreement between the new ( p, ρ, T ) values and the previous measurements of Kleinrahm et al, (18) Händel et al, (19) and Nowak et al, (20) can be ascertained; the deviations are mostly <|5·10 −5 ·ρ|, which is clearly within the uncertainty of both independent sets of measurements. The apparatus used by these experimentalists (18)(19)(20) was the two-sinker densimeter (13,14) of our group.…”
Section: Resultssupporting
confidence: 50%
See 3 more Smart Citations
“…at T ≈ 240 K, the measuring runs of Goodwin (27) and Vennix et al (25) show systematic deviations from the new measurements of up to 2 · 10 −3 · ρ; the uncertainties of these values are given in table 1. In the overlapping temperature range between 240 K and 323 K at pressures p 12 MPa, an excellent agreement between the new ( p, ρ, T ) values and the previous measurements of Kleinrahm et al, (18) Händel et al, (19) and Nowak et al, (20) can be ascertained; the deviations are mostly <|5·10 −5 ·ρ|, which is clearly within the uncertainty of both independent sets of measurements. The apparatus used by these experimentalists (18)(19)(20) was the two-sinker densimeter (13,14) of our group.…”
Section: Resultssupporting
confidence: 50%
“…In the overlapping temperature range between 240 K and 323 K at pressures p 12 MPa, an excellent agreement between the new ( p, ρ, T ) values and the previous measurements of Kleinrahm et al, (18) Händel et al, (19) and Nowak et al, (20) can be ascertained; the deviations are mostly <|5·10 −5 ·ρ|, which is clearly within the uncertainty of both independent sets of measurements. The apparatus used by these experimentalists (18)(19)(20) was the two-sinker densimeter (13,14) of our group. Furthermore, the experimental results of Schamp et al (22) in the temperature range from 273 K to 423 K at pressures up to 26 MPa (not present on the isotherms shown in figure 1) agree very well, often to within |1·10 −4 ·ρ|, with our results.…”
Section: Resultssupporting
confidence: 50%
See 2 more Smart Citations
“…The design of this densimeter was described in detail in previous papers (2,3) and a brief description is given in our most recent paper. (4) Up to now, comprehensive measurements on methane, (2,3,5,6) carbon dioxide, (7)(8)(9) argon, (10,11) ethylene, (12,13) and nitrogen (4,14) have been carried out successfully with this densimeter.…”
Section: Methodsmentioning
confidence: 98%