Measurement Accuracy of a Stand-Alone Oscillometric Central Blood Pressure Monitor: A Validation Report for Microlife WatchBP Office Central

Abstract: Central SBP, PP, and DBP can be measured accurately by a stand-alone automatic BP monitor.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
27
0

Year Published

2014
2014
2024
2024

Publication Types

Select...
4
3
1

Relationship

2
6

Authors

Journals

citations
Cited by 40 publications
(28 citation statements)
references
References 33 publications
0
27
0
Order By: Relevance
“…In the literature, there are 15 studies referenced in PubMed on the evaluation of oscillometric devices to assess systolic cBP [16][17][18][19][20][21][22][23][24][25][26][27][28][29][30]. It includes eight devices and they have all been published in the last 5 years, with more than half of them since 2012.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…In the literature, there are 15 studies referenced in PubMed on the evaluation of oscillometric devices to assess systolic cBP [16][17][18][19][20][21][22][23][24][25][26][27][28][29][30]. It includes eight devices and they have all been published in the last 5 years, with more than half of them since 2012.…”
Section: Discussionmentioning
confidence: 99%
“…Some use a device-specific transfer function applied to the brachial oscillometric tracing [16,[18][19][20][21]24,25]; others apply wave analysis to derive cBP [17,22,23,[26][27][28][29][30]. Many use the brachial oscillometric approach to estimate systolic cBP as oscillometric traces are easy to obtain with a standard cuff and are operator independent.…”
Section: Introductionmentioning
confidence: 99%
“…The patient characteristics and study procedures are described in detail elsewhere [10], [11]. Information relevant to the present study is briefly described below.…”
Section: Methodsmentioning
confidence: 99%
“…When sufficient PWFs are obtained and analyzed, the cSBP and cPP are directly calculated [18]. The DBP is not provided and can be calculated as cSBP - cPP [19,20]. …”
Section: Watchbp Office Centralmentioning
confidence: 99%
“…However, currently there are no standardized validation methods for noninvasive central BP monitors although an international task force has been convened to address this issue. Therefore, for the validation of the WatchBP Office Central the most rigorous approach was chosen; 85 subjects were recruited according to the recommendations for noninvasive validation, and all requirements for the invasive reference standard were also fulfilled [20]. IBP was measured using a fluid-filled catheter which was advanced to the ascending aorta via the right radial artery and placed 2 cm above the aortic valve.…”
Section: Validationmentioning
confidence: 99%