2018
DOI: 10.1016/j.snb.2017.12.100
|View full text |Cite
|
Sign up to set email alerts
|

Masking agent-controlled discriminative Hg2+ and Cu2+ sensing by quinonediimine dye formation of aniline-functionalized silica nanoparticles

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 8 publications
(7 citation statements)
references
References 36 publications
0
7
0
Order By: Relevance
“…The fluorescence was severely quenched by Hg 2+ , and showed nonmeasurable quenching by other cations at identical concentrations except for Cu 2+ and Pb 2+ . For measurement of real water samples, the interference of these species may be eliminated by strategies such as adding citrate , or ethylenediaminetetraacetate , for masking Cu 2+ and adding G-rich DNA for masking Pb 2+ . , Further improvement in the selectivity of Bio-QD probe will be needed in future studies. Furthermore, the Bio-QD-based fluorometry was reperformed with different cuvette and at different temperature from the previous one, but nearly the same fluorescence intensity–Hg 2+ concentration regression curve was obtained (Figure S4), indicating a good reproducibility and robustness of this method.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The fluorescence was severely quenched by Hg 2+ , and showed nonmeasurable quenching by other cations at identical concentrations except for Cu 2+ and Pb 2+ . For measurement of real water samples, the interference of these species may be eliminated by strategies such as adding citrate , or ethylenediaminetetraacetate , for masking Cu 2+ and adding G-rich DNA for masking Pb 2+ . , Further improvement in the selectivity of Bio-QD probe will be needed in future studies. Furthermore, the Bio-QD-based fluorometry was reperformed with different cuvette and at different temperature from the previous one, but nearly the same fluorescence intensity–Hg 2+ concentration regression curve was obtained (Figure S4), indicating a good reproducibility and robustness of this method.…”
Section: Resultsmentioning
confidence: 99%
“…The fluorescence was severely quenched by Hg 2+ , and showed nonmeasurable quenching by other cations at identical concentrations except for Cu 2+ and Pb 2+ . For measurement of real water samples, the interference of these species may be eliminated 34 by strategies such as adding citrate 35,36 or ethylenediaminetetraacetate 37,38 for masking Cu 2+ and adding G-rich DNA for masking Pb 2+ . 39,40 Further improvement in the selectivity of Bio-QD probe will be needed in future studies.…”
Section: Methodsmentioning
confidence: 99%
“…The results of the above experiment are shown in Figure a. To minimize the interference of Cd 2+ and Pb 2+ ions and other metal ions with Hg 2+ ions, citrate buffer was used as a masking agent . To perform the experiment (interference effect in the presence of a masking agent), a reaction mixture of the FeMNP-AlOx probe (2 μL, 0.20 mg), plus various metal ions (2 μL, 100 ng L –1 ) were added to citrate buffer (2 μL, 0.05 M, and pH 5.0) in the first row of a 96-microwell plate and incubated for 5 min.…”
Section: Resultsmentioning
confidence: 99%
“…To minimize the interference of Cd 2+ and Pb 2+ ions and other metal ions with Hg 2+ ions, citrate buffer was used as a masking agent. 41 To perform the experiment (interference effect in the presence of a masking agent), a reaction mixture of the FeMNP-AlOx probe (2 μL, 0.20 mg), plus various metal ions (2 μL, 100 ng L −1 ) were added to citrate buffer (2 μL, 0.05 M, and pH 5.0) in the first row of a 96-microwell plate and incubated for 5 min. Another mixture of PB (194 μL, 10 mM, and pH 7.4), methanol (4 μL, 0.02 mM) and HRP (2 μL, 0.2 IU μL −1 ) was added to the second row of the same 96microwell plate.…”
Section: Acs Earth and Space Chemistrymentioning
confidence: 99%
“…Meanwhile, naphthol group is a good uorophore that can interact with various metal ions [29][30][31]. Thus, the sensor containing both benzothiazole and naphthol moieties might be a suitable platform that can detect Cu 2+ with turn-on system [32][33][34][35][36][37][38][39][40][41].…”
Section: Introductionmentioning
confidence: 99%