2021
DOI: 10.1016/j.sbsr.2020.100392
|View full text |Cite
|
Sign up to set email alerts
|

Manganese oxides/carbon nanowall nanocomposite electrode as an efficient non-enzymatic electrochemical sensor for hydrogen peroxide

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
3
0

Year Published

2021
2021
2022
2022

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 14 publications
(5 citation statements)
references
References 48 publications
2
3
0
Order By: Relevance
“…The calculated sensitivity and LOD of the N-rGO/SPCE toward the sensing of H 2 O 2 using the CV and LSV methods are presented in Table 1 . The obtained results are comparable with previous reports as listed in Table 1 [ 49 , 50 , 51 , 52 , 53 , 54 , 55 , 56 , 57 , 58 , 59 , 60 , 61 , 62 ].…”
Section: Resultssupporting
confidence: 92%
See 2 more Smart Citations
“…The calculated sensitivity and LOD of the N-rGO/SPCE toward the sensing of H 2 O 2 using the CV and LSV methods are presented in Table 1 . The obtained results are comparable with previous reports as listed in Table 1 [ 49 , 50 , 51 , 52 , 53 , 54 , 55 , 56 , 57 , 58 , 59 , 60 , 61 , 62 ].…”
Section: Resultssupporting
confidence: 92%
“…The calculated sensitivity and LOD of the N-rGO/SPCE toward the sensing of H 2 O 2 using the CV and LSV methods are presented in Table 1. The obtained results are comparable with previous reports as listed in Table 1 [49][50][51][52][53][54][55][56][57][58][59][60][61][62]. In previous years, various electrode materials have been explored for the construction of H 2 O 2 sensors.…”
Section: Electrochemical Performance Of N-rgo/spcesupporting
confidence: 89%
See 1 more Smart Citation
“…S11 and S12†). 122–124 Thus, significant quantities of defective oxygen up to 24.56 mol% have been identified (Tables S8 and S9†) further indicating the presence of low valent Mn. (iii) The magnitude of the Mn 3s multiplet splitting (Δ E Mn 3s ).…”
Section: Resultsmentioning
confidence: 98%
“…The quantitative analysis of HPV-containing environments can be carried out by numerous techniques, such as chromatography, electrochemistry, fluorescence, chemiluminescence, chemosensory, etc. Despite the variety of methods, resistive sensors designed based on chemosensory principles (so-called chemoresistors) are advantageous due to their high sensitivity and stability, low power consumption, and relatively easy fabrication technology [ 1 , 2 , 3 , 4 , 5 ].…”
Section: Introductionmentioning
confidence: 99%