2015
DOI: 10.1016/j.snb.2015.01.106
|View full text |Cite
|
Sign up to set email alerts
|

Manganese(II) phosphate nanoflowers as electrochemical biosensors for the high-sensitivity detection of ractopamine

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

3
39
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 99 publications
(43 citation statements)
references
References 33 publications
3
39
0
Order By: Relevance
“…Besides, using different metal ions as inorganic part, several protein-inorganic hybrid nanoflowers were also synthesized. For example, BSA/ZnO [51], BSA/Zn3(PO4) [52], BSA/Mn3(PO4)2 [53], lipase/ Zn3(PO4)2 [54], lipase/Ca3(PO4)2 [55], phenylphosphinic acid/Al(NO3)3.9H2O [56], BSA/AgNO3 [57], protein/Mn3(PO4)2 [58].…”
Section: Organic-inorganic Hybrid Nanoflowersmentioning
confidence: 99%
“…Besides, using different metal ions as inorganic part, several protein-inorganic hybrid nanoflowers were also synthesized. For example, BSA/ZnO [51], BSA/Zn3(PO4) [52], BSA/Mn3(PO4)2 [53], lipase/ Zn3(PO4)2 [54], lipase/Ca3(PO4)2 [55], phenylphosphinic acid/Al(NO3)3.9H2O [56], BSA/AgNO3 [57], protein/Mn3(PO4)2 [58].…”
Section: Organic-inorganic Hybrid Nanoflowersmentioning
confidence: 99%
“…These highly structured materials have primarily been used for the immobilization of enzymes that ultimately achieve superior enzymatic performances. [8][9][10][11] Similar phosphate-based materials have also been synthesized, however, in the absence of organic motifs, that is without macromolecules. 12,13 Materials that display accessible surface areas, 14 high index facets, 15 and sharp edges, 16 and are composed of transition metals, [17][18][19] are potentially useful in the field of electrocatalysis for sensing biochemical analytes.…”
Section: Introductionmentioning
confidence: 99%
“…These techniques basically require a long extraction time, large sample volume, long assay time and considerable organic solvent consumption. Some immunoassays, such as ELISA, strip‐based, electrochemistry‐based and surface plasmon resonance (SPR)‐based immnosensors can provide high specificity and sensitivity with short time needed . However, ELISA and strip‐based immunosenors takes a lot of time for incubation and requires multiple washing steps.…”
Section: Recovery Rates Of Different Concentrations Of Rct In Negativmentioning
confidence: 99%