2021
DOI: 10.3390/cancers13122923
|View full text |Cite
|
Sign up to set email alerts
|

Magnetically Guided Localization Using a Guiding-Marker System® and a Handheld Magnetic Probe for Nonpalpable Breast Lesions: A Multicenter Feasibility Study in Japan

Abstract: Accurate pre-operative localization of nonpalpable lesions plays a pivotal role in guiding breast-conserving surgery (BCS). In this multicenter feasibility study, nonpalpable breast lesions were localized using a handheld magnetic probe (TAKUMI) and a magnetic marker (Guiding-Marker System®). The magnetic marker was preoperatively placed within the target lesion under ultrasound or stereo-guidance. Additionally, a dye was injected subcutaneously to indicate the extent of the tumor excision. Surgeons checked fo… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 11 publications
(6 citation statements)
references
References 29 publications
(48 reference statements)
0
6
0
Order By: Relevance
“…Meanwhile, a distance of 2 mm from the tumor margin was considered adequate for ductal carcinoma in situ (DCIS) [13][14][15][16][17][18]. Table 2 shows the overview of the methods used in non-palpable tumors to mark and remove the area of interest in conservative breast surgery [19][20][21][22][23][24][25][26][27][28].…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Meanwhile, a distance of 2 mm from the tumor margin was considered adequate for ductal carcinoma in situ (DCIS) [13][14][15][16][17][18]. Table 2 shows the overview of the methods used in non-palpable tumors to mark and remove the area of interest in conservative breast surgery [19][20][21][22][23][24][25][26][27][28].…”
Section: Resultsmentioning
confidence: 99%
“…In the case of infra-clinical, non-palpable tumors, it is possible to mark the area of interest with a hook wire placed through the tumor or the injection of a radiotracer (radioguided occult lesion localization -ROLL) [19]. Recently, the use of handheld superparamagnetic devices, such as MagSeed or the Guiding-Marker System, have provided an accurate and reliable localization method in BCS with favorable surgical outcomes [20][21][22] (Table 2). Other alternative, non-radioactive, wire-free localization methods, developed to increase the likelihood of complete tumor removal, include intra-operative ultrasound guidance [23], the LOCalizer radio-frequency identification (RFID) system [24,25], reflector-guided localization through SAVI-SCOUT [26,27], and fluorescence detection after intralesional indocyanine green (ICG) solution injection [113] or intravenous administration was used [28] (Table 2).…”
Section: Preoperative Surgical Planning and Intraoperative Margin Ass...mentioning
confidence: 99%
“…These SLNs were probed using a magnetic handheld device developed by the Department of Electrical Engineering and Information Systems at the University of Tokyo [8]. This probe has also been applied to surgery for non-palpable breast lesions [15].…”
Section: Discussionmentioning
confidence: 99%
“…There are several limitations associated with the use of magnetic-guided surgery, including limited depth of detection and restricted use of metal instruments [38]. Moreover, since the magnetometer must seek out a small tracer collection point, the detection of SLNs by SPIO may be limited.…”
Section: Discussionmentioning
confidence: 99%