2005
DOI: 10.1038/sj.eye.6702013
|View full text |Cite
|
Sign up to set email alerts
|

Macular thickness reduction in eyes with unilateral optic atrophy detected with optical coherence tomography

Abstract: Aims To assess the changes in macular and peripapillary retinal nerve fibre layer (RNFL) thickness in eyes with unilateral optic atrophy and to evaluate the relationship between retinal thickness and visual function. Methods Enrolled were 22 patients with unilateral optic atrophy. Macular thickness at the divided nine areas and peripapillary RNFL thickness in quadrantic sections were measured by optical coherence tomography. Thickness values in the affected eyes were compared with those in the contralateral un… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
6
0
2

Year Published

2009
2009
2016
2016

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 10 publications
(10 citation statements)
references
References 23 publications
2
6
0
2
Order By: Relevance
“…2010). This area was found to be associated with the severity of visual field damage (Kusuhara et al. 2006; Moura et al.…”
Section: Discussionmentioning
confidence: 99%
“…2010). This area was found to be associated with the severity of visual field damage (Kusuhara et al. 2006; Moura et al.…”
Section: Discussionmentioning
confidence: 99%
“…Since Zeimer et al (14) proposed to use macular thickness as an indicator of glaucoma severity, several studies have investigated this idea using technologies to measure retinal thickness such as OCT (18)(19)(20)(21)(22)(23)(24) . Such studies were conducted based on the theory that the macular thickness might be superior to circumpapillary RNFL for quantification of axonal loss, because retinal ganglion cell bodies are 10 to 20 times the diameter of their axons and because the retinal ganglion cell layer is more than one cell thick in the macula (25) .…”
Section: Discussionmentioning
confidence: 99%
“…Reproducibility of RNFLT values obtained by OCT has been previously reported [12]. Macular thickness was also measured using OCT retinal mapping software, which measured thickness of nine divided macular regions including fovea, and the inner and outer rings, each being divided into four quadrants: superior, inferior, temporal, and nasal; the rings have diameters of 2.22 and 3.45 μm respectively [13].…”
Section: Oct Analysismentioning
confidence: 99%