2008
DOI: 10.1111/j.1460-9592.2008.02664.x
|View full text |Cite
|
Sign up to set email alerts
|

MAC‐awake of sevoflurane in children

Abstract: Although MAC-awake changes with age, in the ages where awareness has been reported, MAC-awake was found to be relatively low, and therefore it seems unlikely that age-specific changes to MAC-awake are a cause for awareness in children aged 5-12 years.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
22
1

Year Published

2009
2009
2023
2023

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 49 publications
(23 citation statements)
references
References 13 publications
0
22
1
Order By: Relevance
“…We maintained the predetermined sevo ET for more than 10 min, and data collection was completed before commencing surgery. We continued data sampling until we had obtained six mid‐points of pairs of concentration and approximately 10 changes in direction, which are required to obtain a reliable MAC value using Dixon's up‐and‐down method .…”
Section: Methodsmentioning
confidence: 99%
“…We maintained the predetermined sevo ET for more than 10 min, and data collection was completed before commencing surgery. We continued data sampling until we had obtained six mid‐points of pairs of concentration and approximately 10 changes in direction, which are required to obtain a reliable MAC value using Dixon's up‐and‐down method .…”
Section: Methodsmentioning
confidence: 99%
“…Probit analysis was performed using sas version 9.2 (SAS Institute Inc, Cary, NC, USA). To obtain reliable MAC value using the up‐down method, six midpoints of pair and approximately 10 changes in direction are required (11,12). We assumed that 20 children would be enough to satisfy these concerns.…”
Section: Methodsmentioning
confidence: 99%
“…Under sevoflurane, several studies describe a steady decrease in BIS for increasing sevoflurane concentrations between 1% and 3% . As for propofol, no dose‐related raw EEG pediatric analyses are available to explain this relationship, except for some data describing a decrease in spectral edge frequency for increasing doses of sevoflurane . For higher concentrations, some authors report cases of increase in BIS value .…”
Section: Introductionmentioning
confidence: 99%
“…7,8 As for propofol, no dose-related raw EEG pediatric analyses are available to explain this relationship, except for some data describing a decrease in spectral edge frequency for increasing doses of sevoflurane. 9,10 For higher concentrations, some authors report cases of increase in BIS value. 8,11 There is no clear explanation to this phenomenon, often qualified as "paradoxical.…”
mentioning
confidence: 99%