2018
DOI: 10.1016/j.jiac.2017.09.012
|View full text |Cite
|
Sign up to set email alerts
|

Lymphocyte subset analysis in QuantiFERON-TB Gold Plus and T-Spot.TB for latent tuberculosis infection in rheumatoid arthritis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
8
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 21 publications
(10 citation statements)
references
References 28 publications
2
8
0
Order By: Relevance
“…Therefore, in clinic, if there is a suspicious TB patient with negative IGRA result, it is necessary to distinguish whether it is truenegative, not infected with M. tb, or false-negative due to insu cient lymphocyte count or functional de ciency. It has been reported that lymphocyte subsets were strongly associated with immune response in both QFT-Plus and T-SPOT, and the patients with CD4 + T cell ≥ 650/ L and CD8 + T cell ≥ 400/ L had signi cantly higher positivity rates in both QFT-Plus and T-SPOT, which was a good evidence of our view (23).…”
Section: Lymphocyte Subsets and Clinical Featuressupporting
confidence: 80%
“…Therefore, in clinic, if there is a suspicious TB patient with negative IGRA result, it is necessary to distinguish whether it is truenegative, not infected with M. tb, or false-negative due to insu cient lymphocyte count or functional de ciency. It has been reported that lymphocyte subsets were strongly associated with immune response in both QFT-Plus and T-SPOT, and the patients with CD4 + T cell ≥ 650/ L and CD8 + T cell ≥ 400/ L had signi cantly higher positivity rates in both QFT-Plus and T-SPOT, which was a good evidence of our view (23).…”
Section: Lymphocyte Subsets and Clinical Featuressupporting
confidence: 80%
“…T‐SPOT assay with high specificity and sensitivity can be used to reduce false positive and false negative TST results respectively. Accordance to another study QFT‐Plus which is more accurate than QFT gives more positive results than T‐Spot and seems more sensitive 78 …”
Section: Screening For Latent Tb Infection In Rasupporting
confidence: 51%
“…Accordance to another study QFT-Plus which is more accurate than QFT gives more positive results than T-Spot and seems more sensitive. 78 The low specificity of TST is a common event due to the interference effect of non-TB infections especially in areas with a high prevalence of non-TB involvement and BCG vaccination. 79 Although the IGRA test has high specificity in the detection of TB infection, there are confounding factors that can make positive results uncertain.…”
Section: False Positive Tb Test Results In Ramentioning
confidence: 99%
See 1 more Smart Citation
“…Studies evaluating the new QFT-Plus assay are continuing to emerge and have primarily been performed in patients outside North America with active TB infection or as part of TB contact investigations (9,11,12,18,19). Fewer reports have focused on the performance of this new IGRA in patients with LTBI (13,20,21). To date, a single manuscript evaluating this assay has been published from the United States, which compared the performance of the QFT-Plus to that of the QFT-GIT for TB screening of HCWs practicing in a low-TB-incidence setting (8).…”
Section: Discussionmentioning
confidence: 99%