2020
DOI: 10.2298/vsp180622167i
|View full text |Cite
|
Sign up to set email alerts
|

Lung ultrasound for volume status assessment in chronic hemodialysis patients

Abstract: Apstrakt Uvod / Cilj. Procena stanja volemije pacijenata na hroničnom programu hemodijalize (HD) je teška uprkos postojećim razvijenim tehnikama. Cilj ove studije je bio da pokaže adekvatnost i efikastnost ultrazvuka pluća (UZP) i B linijskog skora (BLS) u proceni stanja volemije kod pacijenata na HD u poređenju sa drugim tehnikama: dijametrom donje šuplje vene (DŠVD) i B tipom natriuretskog peptida (BNP). Metode.UZP, ehokardiografija sa ultrasonografijom donje šuplje vene u inspirijumu (DŠVDi) i ekspirijumu (… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
3
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
1
1

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(3 citation statements)
references
References 20 publications
(39 reference statements)
0
3
0
Order By: Relevance
“…Such artifacts, in reference to Kerley B lines on chest X-ray, are described in lung ultrasound as comet-tail artifacts formed as the ultrasound beam meets thickened interlobular septa filled with water in case of interstitial lung oedema [21] [22]. This method is easy, fast, cheap, and non-invasive, requiring just an ultrasound machine with a linear, convex, or sectoral transducer [21].…”
Section: Introductionmentioning
confidence: 99%
“…Such artifacts, in reference to Kerley B lines on chest X-ray, are described in lung ultrasound as comet-tail artifacts formed as the ultrasound beam meets thickened interlobular septa filled with water in case of interstitial lung oedema [21] [22]. This method is easy, fast, cheap, and non-invasive, requiring just an ultrasound machine with a linear, convex, or sectoral transducer [21].…”
Section: Introductionmentioning
confidence: 99%
“…Lung ultrasound can evaluate extravascular lung water by identifying B-lines, which are vertical artifacts arising from the pleural line and extending to the edge of the screen, that move synchronous with respiratory. Such artifacts, in reference to Kerley B lines on chest X-ray, are described in lung ultrasound as comet-tails artifacts formed as ultrasound beam meet thickened interlobular septa lled with water in case of interstitial lung oedema (20,21). This method is easy, fast, cheap and non-invasive, requiring just an ultrasound machine with a linear, convex or sectoral transducer (20).…”
mentioning
confidence: 99%
“…Such artifacts, in reference to Kerley B lines on chest X-ray, are described in lung ultrasound as comet-tails artifacts formed as ultrasound beam meet thickened interlobular septa lled with water in case of interstitial lung oedema (20,21). This method is easy, fast, cheap and non-invasive, requiring just an ultrasound machine with a linear, convex or sectoral transducer (20).…”
mentioning
confidence: 99%