2010
DOI: 10.1016/j.jlumin.2009.10.012
|View full text |Cite
|
Sign up to set email alerts
|

Luminescence properties of highly Cr co-doped Nd:YAG powder produced by sol–gel method

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
15
0

Year Published

2011
2011
2019
2019

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 37 publications
(18 citation statements)
references
References 20 publications
(29 reference statements)
1
15
0
Order By: Relevance
“…Typical Cr 3+ luminescence peaks were also observed in all the spectra, which corresponds to the above described photoluminescence emission spectrum. They can be again ascribed to the Cr 3+ d-d transition from its 2 E to 4 A 2 states [6], [7]. In addition, elevated emission intensity around 740 nm in the Gd50YAG was also observed as well as in its photoluminescence spectrum.…”
Section: Resultsmentioning
confidence: 78%
See 2 more Smart Citations
“…Typical Cr 3+ luminescence peaks were also observed in all the spectra, which corresponds to the above described photoluminescence emission spectrum. They can be again ascribed to the Cr 3+ d-d transition from its 2 E to 4 A 2 states [6], [7]. In addition, elevated emission intensity around 740 nm in the Gd50YAG was also observed as well as in its photoluminescence spectrum.…”
Section: Resultsmentioning
confidence: 78%
“…4. All the samples showed a sharp luminescence around 700 nm due to Cr 3+ d-d transition from its excited state of 2 E to 4 A 2 [6], [7]. In the spectra of Cr:YAG and Cr:Gd25YAG, four emission peaks were observed around 680, 690, 700 and 730 nm, which are related to the luminescence of Cr 3+ ion incorporated into the garnet phase.…”
Section: Resultsmentioning
confidence: 92%
See 1 more Smart Citation
“…The decrease in the emission intensity is caused by the concentration quenching of Bi 3+ . The total energy transfer efficiency depends not only on the probability of energy transfer from sensitizer to activator, but also on that between the sensitizers [15,17]. The energy transfer efficiency increases with the decrease of the distance between the sensitizer and activator (or sensitizer).…”
Section: Resultsmentioning
confidence: 99%
“…In the photo-luminescence spectra, each sample demonstrated broad band associated with 4 T 2 →A 2 transitions, and a detectable narrow peak at approximately 693 nm originating from 2 E→ 4 A 2 transition (R-lines) was clearly observed for the Cr:YGG (Fig. 7) [15][16][17]. Although other samples should also have these R-lines, such peaks were not well-seen.…”
Section: Materials and Experimental Methodsmentioning
confidence: 96%