1998
DOI: 10.1016/s0301-679x(98)00005-x
|View full text |Cite
|
Sign up to set email alerts
|

Lubrication and wear of ultra-high molecular weight polyethylene in total joint replacements

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

8
176
0
1

Year Published

2000
2000
2011
2011

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 302 publications
(185 citation statements)
references
References 23 publications
8
176
0
1
Order By: Relevance
“…Surface wear of polyethylene is not only determined by sliding distance and load [1], but also by other variables including cross shear [3,25] and the surface area [2] of the polyethylene being worn. We therefore investigated to what degree surface wear was reduced by (1) reduced levels of cross shear in rotating platform mobile-bearing knees, and (2) reduced bearing surface area in low conforming fixed-bearing knees.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…Surface wear of polyethylene is not only determined by sliding distance and load [1], but also by other variables including cross shear [3,25] and the surface area [2] of the polyethylene being worn. We therefore investigated to what degree surface wear was reduced by (1) reduced levels of cross shear in rotating platform mobile-bearing knees, and (2) reduced bearing surface area in low conforming fixed-bearing knees.…”
Section: Discussionmentioning
confidence: 99%
“…In fixed-bearing knees increased cross shear and increased wear reportedly occurs with higher levels of activity, whether it be increased rotation [22] or increased lateral shift with lift off [18]. Increased cross shear also increases wear in the hip [3,25]. The rotating platform mobile-bearing knee design, which accommodates rotation on the lower articulating surface, decouples complex motions to simple unidirectional motion and low cross shear on both articulating surfaces (Fig.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Thus, orthopaedic manufacturers invested substantial resources in the commercialization of second-generation metal-on-metal [3,24,40] and ceramic-on-ceramic [14,47,107,126] hip bearings during the 1990s, culminating in the growth in the adoption of these bearings at the start of the 21st century [18]. Concurrently, polyethylene researchers at multiple institutions around the world confirmed the finding that elevated doses of radiation crosslinking would reduce wear rates by an order of magnitude during in vitro hip simulator testing [95,103,133]. Clinical researchers in Japan and South Africa reported successful long-term case series initiated in the 1970s in which polyethylene had been exposed to elevated doses of gamma radiation [56,109,111] and silane chemistry [144].…”
Section: History and Development Of Hxlpementioning
confidence: 94%
“…Studies concerning wear behavior of UHMWPE sliding against stainless steel have been performed, for example Atkinson et al [9], Wang et al [17,21] and Wang and Li [22]. According to their descriptions, there are three periods existing in a sliding wear process: the wearing-in period, the steady-state period and the severe wear period.…”
Section: Wear Mechanismmentioning
confidence: 99%