1997
DOI: 10.1117/12.266761
|View full text |Cite
|
Sign up to set email alerts
|

<title>New high-efficiency ion-trap mobility detection system for narcotics</title>

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
2
0
2

Year Published

1998
1998
2020
2020

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 8 publications
(4 citation statements)
references
References 0 publications
0
2
0
2
Order By: Relevance
“…For better understanding of the requirements to build a field switching (FS) ion shutter for a dual drift tube IMS, the basic setup of such an ion shutter for a single drift tube IMS is explained shortly. FS ion shutters are characterized by a field free ionization region ,− , and the injection of accumulated ions into a drift tube by switching the field inside the ionization region. For a single drift tube IMS the ionization region is located between a pusher electrode and an injection grid, which separates the ionization region from the drift tube.…”
Section: Field Switching Ion Shutter For Axial Dual Drift Tube Imsmentioning
confidence: 99%
“…For better understanding of the requirements to build a field switching (FS) ion shutter for a dual drift tube IMS, the basic setup of such an ion shutter for a single drift tube IMS is explained shortly. FS ion shutters are characterized by a field free ionization region ,− , and the injection of accumulated ions into a drift tube by switching the field inside the ionization region. For a single drift tube IMS the ionization region is located between a pusher electrode and an injection grid, which separates the ionization region from the drift tube.…”
Section: Field Switching Ion Shutter For Axial Dual Drift Tube Imsmentioning
confidence: 99%
“…Если условие ортогональности РИ: выполняется, то при d/λ 0 =1/2 из (5) следует перемещение луча в секторе ±90° за время τ u . В литературе [16,17] этот эффект получил название «сверхбыстрого сканирования луча» (СБСЛ). Ширина зоны обзора здесь регулируется шагом решётки d, а однозначность -выбором τ u .…”
Section: условия перехода от рлс с фар к технологии Mimo рлс при испоunclassified
“…где -спектральная плотность чётно-симметричного степенного сигнала; Для автокорреляционной функции (15), с учётом (2) и (17), получим ,…”
Section: российский технологический журнал 2016 том 4 №unclassified
“…For ion sources that can ionize inside a field-free region, the field switching (FS) ion shutter is an alternative with superior performance. The generated ions are accumulated inside the field-free region prior to quickly pushing all ions into the drift region as a single narrow ion packet.…”
mentioning
confidence: 99%