Compact and Sensitive Dual Drift Tube Ion Mobility Spectrometer with a New Dual Field Switching Ion Shutter for Simultaneous Detection of Both Ion Polarities

Abstract: Ion mobility spectrometers (IMS) with field switching ion shutters are an excellent choice for trace gas detection, being extremely sensitive while having fast response times. However, as different target molecules may form positive, negative, or even ions of both polarities, it is beneficial to simultaneously detect both ion polarities. Here, we present a dual drift tube IMS with a new dual field switching ion shutter for gating both ion polarities and an X-ray ionization source in orthogonal configuration. T… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
13
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 12 publications
(14 citation statements)
references
References 16 publications
(34 reference statements)
1
13
0
Order By: Relevance
“…It consists of a main body and a thin metal grid with 200 μm diameter holes arranged in a 12 × 12 pattern. The ion source is designed completely symmetrically, allowing the pusher electrode to be replaced by a second ion shutter and drift tube, forming an axially arranged dual drift tube IMS with two extended field ion switching shutters . Using two ratios allows describing the various gas flows shown in Figure b) more easily.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…It consists of a main body and a thin metal grid with 200 μm diameter holes arranged in a 12 × 12 pattern. The ion source is designed completely symmetrically, allowing the pusher electrode to be replaced by a second ion shutter and drift tube, forming an axially arranged dual drift tube IMS with two extended field ion switching shutters . Using two ratios allows describing the various gas flows shown in Figure b) more easily.…”
Section: Methodsmentioning
confidence: 99%
“…The ion source is designed completely symmetrically, allowing the pusher electrode to be replaced by a second ion shutter and drift tube, forming an axially arranged dual drift tube IMS with two extended field ion switching shutters. 30 Using two ratios allows describing the various gas flows shown in Figure 1b) more easily. The outlet to inlet factor k OI between the sample gas outlet flow Q sample,out and the sample gas inlet flow Q sample,in as given by eq 1 is a measure for the amount of clean gas used to focus the sample gas and ranges from 0 ≤ k OI < ∞.…”
Section: ■ Experimental Sectionmentioning
confidence: 99%
“…22−30 However, a dual drift tube approach is fraught with challenges as well, including the uniform transfer of ions into each individual drift tube which may require completely new ion shutter designs to remedy. 27 Furthermore, the size reduction of two single IMS is limited as still two drift tubes and two sets of control electronics are required.…”
Section: ■ Introductionmentioning
confidence: 99%
“…IM approaches can be broadly classified into linear and non-linear methods. In linear methods, such as drift tube IMS (DTIMS), 4,5 travelling wave IMS, 6,7 and trapped IMS, 8,9 ions are separated under a relatively weak electric field ( E ) such that their mobilities ( K ) increase proportionally with the electric field. In low field IM methods, ion separation depends strongly on the cross section and reduced mass of the ion-neutral collision pair, and the charge state of the ion.…”
Section: Introductionmentioning
confidence: 99%