Miniaturized Drift Tube Ion Mobility Spectrometer with Ultra-Fast Polarity Switching

Abstract: Ion mobility spectrometers (IMS) are well suited for detecting trace gases down to levels at ppb v and even ppt v within 1 s of analysis time when using chemical ionization. The measuring principle is based on the separation and detection of the ionized constituents of a sample. Depending on the sample composition, certain ionization sources create both positive and negative analyte ions, but the simultaneous detection of both ion polarities usually requires two drift tubes. Contained within this effort, we pr… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
8
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 10 publications
(8 citation statements)
references
References 34 publications
0
8
0
Order By: Relevance
“…The purpose of aperture gird in IMS instrument is to prevent the generation of induced current as the ion swarm approaches the detector, so that the voltage stability of aperture grid is of key importance for the quality of signal measured on the detector [24]. Normally a large capacitor C, which capacitance value is between 100 nF and 1 µF, is arranged between the aperture grid and ground, in parallel to the voltage dividing resistor R, to stabilized the potential difference between the aperture grid and the ion detector and hence reduce the noise, as shown in Figure 3a.…”
Section: Instrumentsmentioning
confidence: 99%
See 4 more Smart Citations
“…The purpose of aperture gird in IMS instrument is to prevent the generation of induced current as the ion swarm approaches the detector, so that the voltage stability of aperture grid is of key importance for the quality of signal measured on the detector [24]. Normally a large capacitor C, which capacitance value is between 100 nF and 1 µF, is arranged between the aperture grid and ground, in parallel to the voltage dividing resistor R, to stabilized the potential difference between the aperture grid and the ion detector and hence reduce the noise, as shown in Figure 3a.…”
Section: Instrumentsmentioning
confidence: 99%
“…If the switching of polarity takes a few seconds and the device happens to work under the negative mode when the TATP is sampled, the analyte will be gone when the polarity is switched back to positive mode, ending up a false negative result. In another application, when used as a detector for GC the switching also has to be fast as possible, since the elution peak only last for seconds and each measurement must take shorter time than the standard deviation to restore the gaussian peak with high fidelity [24].…”
Section: Introductionmentioning
confidence: 99%
See 3 more Smart Citations