<p>Effectiveness of Breast and Eye Shielding During Cervical Spine Radiography: An Experimental Study</p>

Abstract: This study assessed the effectiveness of breast and eye shielding and measured the radiation dose to radiosensitive tissues (eyes and breasts) due to scatter radiation during cervical spine X-ray radiography examinations. Methods: Using an anthropomorphic phantom, the scattered radiation dose was measured before and after the placement of the lead shield over the eyes and breasts in the anteroposterior (AP) and left lateral projection. A regression formula was utilized to determine the exposure. Mean values an… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
13
3

Year Published

2021
2021
2022
2022

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 18 publications
(21 citation statements)
references
References 22 publications
1
13
3
Order By: Relevance
“…57 While the study did not investigate the occupational radiation dose, it is worth emphasising the importance of radiation safety for all RWF members 58 ; corrective actions are needed to comply with radiation safety and protection during radiology examinations. 59 Moreover, proper radiation protection for patients should be implemented 60 to ensure radiation safety practice in both routine and crisis situations.…”
Section: Discussionmentioning
confidence: 99%
“…57 While the study did not investigate the occupational radiation dose, it is worth emphasising the importance of radiation safety for all RWF members 58 ; corrective actions are needed to comply with radiation safety and protection during radiology examinations. 59 Moreover, proper radiation protection for patients should be implemented 60 to ensure radiation safety practice in both routine and crisis situations.…”
Section: Discussionmentioning
confidence: 99%
“…In another work with lumbosacral x-ray carried out in Slovenia, Mekis et al [5] observed as much as 80% reduction in breast dose when a 0.5 mm lead equivalent shielding material was used. A reduction of about 99% was reported in a work in United Arab Emirates [11]. Statistically significant dose reductions of 42% was also reported in a work published in America [12].…”
Section: Discussionmentioning
confidence: 69%
“…This irradiation tends to increase the risk to cancer in exposed persons and gene mutation in descendants of exposed persons [1,6]. To reduce or prevent scatter to the breasts, apparel shielding has been recommended [1,6,11]. This work was an attempt to provide further evidence to consolidate the recommendations in order to have a paradigm shift in current practice at our facility where apparel shielding for patients is not yet being implemented.…”
Section: Discussionmentioning
confidence: 99%
“…Lead (Pb) shields are commonly used to protect patients during radiology procedures (5,6). The importance of the shielding materials for medical and industrial applications was highlighted by different investigations (7)(8)(9)(10). In particular, a remarkable reduction in absorbed radiation dose for testes, ovaries, eyes, and breasts was observed via experimental studies that utilized shielding during radiology procedures.…”
Section: Introductionmentioning
confidence: 99%
“…Target organs are situated in the primary field of radiation. Even though non-target organs are away from the field of radiation, they were also affected by the scatter radiation (9)(10)(11)(12)(13).…”
Section: Introductionmentioning
confidence: 99%