2017
DOI: 10.18520/cs/v112/i04/802-810
|View full text |Cite
|
Sign up to set email alerts
|

<i>In situ</i> U-Pb Zircon Micro-Geochronology of MCT Zone Rocks in the Lesser Himalaya Using LA–MC–ICPMS Technique

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
12
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
8

Relationship

3
5

Authors

Journals

citations
Cited by 23 publications
(12 citation statements)
references
References 26 publications
(38 reference statements)
0
12
0
Order By: Relevance
“…However, we used Plesovice (TIMS reference age 337.13 ± 0.37 Ma) (Sláma et al 2008) as a secondary standard for U-Pb geochronology. The complete methodology adopted in this paper is similar to that described by Mukherjee et al (2017). Off-line processing of the data obtained from the mass spectrometer was done using Iolite version 2.5 (Paton et al 2011).…”
Section: Methodsmentioning
confidence: 99%
“…However, we used Plesovice (TIMS reference age 337.13 ± 0.37 Ma) (Sláma et al 2008) as a secondary standard for U-Pb geochronology. The complete methodology adopted in this paper is similar to that described by Mukherjee et al (2017). Off-line processing of the data obtained from the mass spectrometer was done using Iolite version 2.5 (Paton et al 2011).…”
Section: Methodsmentioning
confidence: 99%
“…The analyses were carried out with a spot diameter of 20 µm (the spots were positioned relative to the CL images), a repetition rate of 5 Hz, an energy density of 4 J/cm 2 and 75% laser intensity. Instrumental conditions, analysis methods and data acquisition were similar to those described by Mukherjee et al [2017]. For fractionation correction and calculation of results, we used the Z 91500 zircon standard (Thermal Ionization Mass Spectrometry [TIMS] normalization data 206 Pb/ 238 U = 1062.32 ± 2.22 [2 sigma]; Wiedenbeck et al [1995]) and the accuracy was later checked using the Plesovice zircon standard (Isotope Dilution [ID] TIMS 206 Pb/ 238 U age = 337.13 ± 0.37 Ma; Slama et al [2008]) as the external standard.…”
Section: La-mc-icpms -Zircon U-pb Geochronologymentioning
confidence: 99%
“…A laboratory dedicated to in situ zircon geochronology and Hf-isotope analysis has been set up at the Wadia Institute of Himalayan Geology (WIHG) during the last few years comprising LA-MC-ICPMS-Q-ICPMS. Basic analytical protocols and performance information is available in Mukherjee et al (2017). A mixed collector configuration of MC-ICPMS is used for zircon geochronology.…”
Section: Wadia Institute Of Himalayan Geology (Wihg)mentioning
confidence: 99%