2019
DOI: 10.3390/electronics8020226
|View full text |Cite
|
Sign up to set email alerts
|

LS-Solar-PV System Impact on Line Protection

Abstract: Large-scale photovoltaic power station access to the grid will profoundly change the fault current characteristics of the power station’s outgoing lines. This change results in adaptive problems in traditional protection phase selection components, which may cause incorrect actions in reclosing, protection ranging, and distance protection. Based on the fault current characteristics of the large-scale photovoltaic power station transmission line, this paper analyzes the adaptability of the phase current differe… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
9
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
5
1

Relationship

3
3

Authors

Journals

citations
Cited by 10 publications
(9 citation statements)
references
References 22 publications
0
9
0
Order By: Relevance
“…In this paper, the DBN-DNN model source training data adopts the data of August 2019 (1)(2)(3)(4)(5)(6)(7)(8)(9)(10)(11)(12)(13)(14)(15)(16)(17)(18)(19)(20), and the data of the task to be calculated adopts the data of August 21, 2020. Due to the randomness of the output of wind power and photovoltaic power, the model training and calculation are difficult.…”
Section: B Sample Datamentioning
confidence: 99%
See 1 more Smart Citation
“…In this paper, the DBN-DNN model source training data adopts the data of August 2019 (1)(2)(3)(4)(5)(6)(7)(8)(9)(10)(11)(12)(13)(14)(15)(16)(17)(18)(19)(20), and the data of the task to be calculated adopts the data of August 21, 2020. Due to the randomness of the output of wind power and photovoltaic power, the model training and calculation are difficult.…”
Section: B Sample Datamentioning
confidence: 99%
“…In addition, the data required for calculation will be missing, incomplete collection or collection errors [12]. Therefore, finding a fast, accurate, and highly error-tolerant theoretical online calculation method for the loss of data, so as to formulate practical loss reduction measures to reduce the loss of the network, is an urgent problem for power companies to solve [13][14].…”
Section: Introductionmentioning
confidence: 99%
“…Based on the above structure, the steady state construction of the PV cell is used in this paper, for which the analog equivalent circuit is shown in Figure 3, where I PH is the photo-generated current of the semiconductor PN junction, I D is PN junction forward conduction current, R L and R S are the leakage resistance and contact resistance between the electrodes on both sides of the PN junction, and I L is the inter-electrode leakage current. The characteristic function is a single exponential equivalent model [29,30], as follows:…”
Section: Power Flow Calculation Of the Pv Power System Based On The Mmentioning
confidence: 99%
“…In this paper, = , ≈ , and ≈ ∞ are approximated in the modeling, so that the external characteristics of the PV cell are simplified to Formula (5), and the relationship between parameters , and the respective feature quantities, is as shown in Formula (6). The characteristic function is a single exponential equivalent model [29,30], as follows:…”
Section: Power Flow Calculation Of the Pv Power System Based On The Mmentioning
confidence: 99%
See 1 more Smart Citation