Low kV settings CT angiography (CTA) with low dose contrast medium volume protocol in the assessment of thoracic and abdominal aorta disease: a feasibility study

Abstract: Minutolo O, Sironi S. Low kV settings CT angiography (CTA) with low dose contrast medium volume protocol in the assessment of thoracic and abdominal aorta disease: a feasibility study. Br J Radiol 2015;88:20140140.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

2
32
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 67 publications
(35 citation statements)
references
References 22 publications
2
32
0
Order By: Relevance
“…Regarding the DLP, the median value of our study was more or less comparable to Cornea et al [9] and Ippolito et al [6] and higher than Zhang et al [7], Manheimer et al [10] and Beeres et al [8]. Christensen et al [5] 32x0.6 120 2.4 13.9 -Zhang et al [7] 64x0.6 100 1.2 5.6 191.3 Cornea et al [9] 64x0.625 100 1.375 -648.71 Manheimer et al [10] 64x0.625 120 --325.6 Beeres et al [8] 128x0.6 100 3.0 3.70 273.0 Ippolito et al [6] 128x0 Figure 1. The distribution of DLP values from chest CTA examinations using a 16-slice system.…”
Section: Resultssupporting
confidence: 89%
See 1 more Smart Citation
“…Regarding the DLP, the median value of our study was more or less comparable to Cornea et al [9] and Ippolito et al [6] and higher than Zhang et al [7], Manheimer et al [10] and Beeres et al [8]. Christensen et al [5] 32x0.6 120 2.4 13.9 -Zhang et al [7] 64x0.6 100 1.2 5.6 191.3 Cornea et al [9] 64x0.625 100 1.375 -648.71 Manheimer et al [10] 64x0.625 120 --325.6 Beeres et al [8] 128x0.6 100 3.0 3.70 273.0 Ippolito et al [6] 128x0 Figure 1. The distribution of DLP values from chest CTA examinations using a 16-slice system.…”
Section: Resultssupporting
confidence: 89%
“…The median value of CTDI vol from our study was comparable to Christensen et al [5] and Ippolito et al [6] and higher than Zhang et al [7] and Beeres et al [8]. Regarding the DLP, the median value of our study was more or less comparable to Cornea et al [9] and Ippolito et al [6] and higher than Zhang et al [7], Manheimer et al [10] and Beeres et al [8].…”
Section: Resultssupporting
confidence: 81%
“…Ippolito D. et al [2], using a 256-row CT, significantly decreased the radiation exposure by ECGgated Aortic CT.…”
Section: Discussionmentioning
confidence: 99%
“…Concerning contrast reduction, a significant contribution came from Ippolito D. et al [2] who, using 256-row CT, administered only 30 ml of contrast medium.…”
Section: Discussionmentioning
confidence: 99%
“…The key feature of the “double‐low” CTA technique is improvement of the contrast between the contrast medium in the vessels and the adjacent tissues. At present, it is a frequent practice to apply the “double‐low” technique in abdominal CTA for individuals with low‐to‐medium BMI by lowering tube voltage . With the decrease in tube voltage, X‐ray photon energy is reduced, and the photoelectric effect is significantly increased when the photon energy level approaches that of tissues or structures containing elements of high atomic number (e.g.…”
Section: Discussionmentioning
confidence: 99%