2014
DOI: 10.3109/10717544.2014.972528
|View full text |Cite
|
Sign up to set email alerts
|

Low-intensity focused ultrasound mediated localized drug delivery for liver tumors in rabbits

Abstract: ADM-NMCs combined with LIFU could inhibit the rabbits VX2 liver tumor progress by delaying the tumor proliferation and accelerating apoptosis, which presents a novel process for liver tumor targeting chemotherapy.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
28
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 38 publications
(28 citation statements)
references
References 32 publications
0
28
0
Order By: Relevance
“…An LIFU instrument 23 (LM.SC051 ACA; Institute of Ultrasound Imaging of Chongqing Medical Sciences, Chongqing, People's Republic of China) with a driving frequency of 1.0 MHz, focal length of 1.5 cm, focus area of 0.4 cm 2 , acoustic intensity in a focal spot of 0.4-3.2 W/cm 2 , and 50% duty cycle was used in this study in a pulse wave (PW) mode with different acoustic intensities (0.8, 1.6, 2.4, and 3.2 W/cm 2 ) for 2 min. LIFU acoustic intensity was measured with a hydrophone (HNA-0400; ONDA Corp., Sunnyvale, CA, USA).…”
Section: Fa-nd Thermal Evaporationmentioning
confidence: 99%
“…An LIFU instrument 23 (LM.SC051 ACA; Institute of Ultrasound Imaging of Chongqing Medical Sciences, Chongqing, People's Republic of China) with a driving frequency of 1.0 MHz, focal length of 1.5 cm, focus area of 0.4 cm 2 , acoustic intensity in a focal spot of 0.4-3.2 W/cm 2 , and 50% duty cycle was used in this study in a pulse wave (PW) mode with different acoustic intensities (0.8, 1.6, 2.4, and 3.2 W/cm 2 ) for 2 min. LIFU acoustic intensity was measured with a hydrophone (HNA-0400; ONDA Corp., Sunnyvale, CA, USA).…”
Section: Fa-nd Thermal Evaporationmentioning
confidence: 99%
“…11, 16, 32, 33 Several prior studies have examined the use of ultrasound to enhance drug release from polymer implants. 5, 6, 22 In contrast to the current study, these studies included gas bubbles or generation of heat, which were able to drive drug release via inertial cavitation and/or mild hyperthermia. Ultrasound exposure has also been shown to significantly increase degradation rate of the polymer matrix, especially polyanhydrides, or reform the structure of the polymer such as cross-link hydrogel or shape memory polymers.…”
Section: Discussionmentioning
confidence: 97%
“…11, 32, 33 In this process, typically it is the mechanical and thermal effects which are associated with an increase in penetration, perfusion or release of the drug. 6, 33 Recently ultrasound was also used to control release of insulin from a gel-like network system consisting of alginate-coated nanoparticles and chitosan-coated nanoparticles. During treatment with focused ultrasound, the network was deformed and promoted insulin release.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Contrast agent microbubbles combined with ultrasound-mediated targeted transfection of gene is a new, non-invasive, effective and convenient technique and can be used in the treatment of tumor or cardiovascular disease (Gong et al, 2014;Liao et al, 2014;Sun et al, 2014). Ultrasound-triggered microbubble destruction is considered as a method of target gene therapy for specific organ.…”
Section: Introductionmentioning
confidence: 99%