Low energy analysis techniques for CUORE

Abstract: CUORE is a tonne-scale cryogenic detector operating at the Laboratori Nazionali del Gran Sasso (LNGS) that uses tellurium dioxide bolometers to search for neutrinoless double-beta decay of 130 Te. CUORE is also suitable to search for low energy rare events such as solar axions or WIMP scattering, thanks to its ultra-low background and large target mass. However, to conduct such sensitive searches requires improving the energy threshold to 10 keV. In this paper, we describe the analysis techniques developed for… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
15
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
7
1

Relationship

4
4

Authors

Journals

citations
Cited by 23 publications
(15 citation statements)
references
References 42 publications
0
15
0
Order By: Relevance
“…A total of 984 of 988 channels are functioning. Thermal event pulses are identified by a software derivative trigger with channel-dependent thresholds ranging from 20 to a few hundred keV; we anticipate reducing these thresholds for future low-energy studies [44,45]. The rise and fall times of thermal pulses are on the order of 100 ms and 400 ms, respectively.…”
mentioning
confidence: 99%
“…A total of 984 of 988 channels are functioning. Thermal event pulses are identified by a software derivative trigger with channel-dependent thresholds ranging from 20 to a few hundred keV; we anticipate reducing these thresholds for future low-energy studies [44,45]. The rise and fall times of thermal pulses are on the order of 100 ms and 400 ms, respectively.…”
mentioning
confidence: 99%
“…The 0νββ sensitivity and exposure that CUORE has attained demonstrate that the cryogenic calorimetric technique is scalable to the tonne-scale detector masses and multiyear live times necessary to be competitive in the current international 0νββ decay search program. The large accumulated exposure paired with the low energy thresholds of CUORE's calorimeters will also enable searches for other new physics in the low energy regime [49].…”
Section: Discussionmentioning
confidence: 99%
“…We set a common analysis threshold of 40 keV to guarantee that our trigger efficiency is above 90% for the majority (97%) of our detectors while also being low enough to reliably remove multi-Compton events from the ROI with the anti-coincidence cut. Our improved ability to detect low-energy events using this OT method also increases the efficiency with which we can reconstruct events that release energy in more than one calorimeter, improving our background reconstruction ability [49,53].…”
Section: Acknowledgmentsmentioning
confidence: 99%
“…The data analysis procedure is described in detail in [70] and mostly follows the strategy adopted for CUORE-0 [96]. Recent improvements include a significant lowering of the detectors energy threshold thanks to the application of the optimum trigger algorithm based on the matched filter technique [98,99] and the introduction of a new methodology for pulse shape analysis with higher efficiencies [100]. The energy thresholds have a relevant role on the effectiveness of the anti-coincidence analysis.…”
Section: Beyond Standard Model Decay Of 130 Tementioning
confidence: 99%