1998
DOI: 10.1097/00005373-199806000-00007
|View full text |Cite
|
Sign up to set email alerts
|

Long-Term Results of the External Fixation of Distal Radius Fractures

Abstract: The external fixator is a versatile tool in the treatment of intra-articular and extra-articular fractures of the distal radius. The rate of algodystrophy (reflex sympathetic dystrophy) was 6%, and wrist stiffness was not found in our series.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
18
0
9

Year Published

2002
2002
2021
2021

Publication Types

Select...
6
1

Relationship

3
4

Authors

Journals

citations
Cited by 48 publications
(30 citation statements)
references
References 14 publications
2
18
0
9
Order By: Relevance
“…On comparison of anatomical results with functional results it was found that anatomical results were satisfactory in 83.33% and functional results were satisfactory in 86.66%. Our results supports the hypothesis by many authors that ultimate functional results after fractures of the distal radius correlate directly with restoration of normal anatomy [2,12,20,21] .…”
Section: Discussionsupporting
confidence: 92%
See 2 more Smart Citations
“…On comparison of anatomical results with functional results it was found that anatomical results were satisfactory in 83.33% and functional results were satisfactory in 86.66%. Our results supports the hypothesis by many authors that ultimate functional results after fractures of the distal radius correlate directly with restoration of normal anatomy [2,12,20,21] .…”
Section: Discussionsupporting
confidence: 92%
“…The complication rate in our series is 30%. It is similar to the reported range of 32-34% in the literature [20,21] , but higher than the studies of others [8,22] which reported a rate ranging from 4-17%. The higher rate in our series compared to these series were due to the fact that we didn't use limited open surgical technique (open placement of pins) in the initial cases.…”
Section: Discussionsupporting
confidence: 90%
See 1 more Smart Citation
“…The initial treatment of the wrist fractures consisted of closed reduction and external fixation (AO-ASIF mini external fixator, Stratec Medical, Oberdorf, Switzerland) in a standardized technique using manual traction [16]. The procedure was carried out within 24 h of the accident.…”
Section: Methodsmentioning
confidence: 99%
“…Restoration of radial length, radial tilt angle and congruity of articular surfaces is important for good functional results [3] . There is evidence to suggest that anatomical articular reduction greatly reduce the incidence of post traumatic Osteoarthritis [4] .…”
Section: Lateral Viewmentioning
confidence: 99%