2005
DOI: 10.1088/0957-0233/16/11/013
|View full text |Cite
|
Sign up to set email alerts
|

Long-period gratings in optical fibres for chemical sensor applications

Abstract: Analysis of long-period fibre grating (LPG) parameters and their mutual dependences are presented. LPGs were studied and optimized specifically for chemical sensor applications. It was found that absorption by the fibre cladding of some environmental gases, such as oxygen or water vapour, may result in a false signal generation. The principal limitation of the sensor sensitivity is connected to the longitudinal homogeneity of the fibre refractive indices.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

1
3
0

Year Published

2007
2007
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 12 publications
(4 citation statements)
references
References 23 publications
1
3
0
Order By: Relevance
“…Recently, Peshko et al have described the use of commercial PDMS to coat an LPG for the detection of toluene. 15 Despite the fact that the PDMS coating was not doped and therefore its refractive index was likely lower than 1.42, toluene could be detected at levels comparable to those in our study (100 ppm). The high sensitivity achieved in this case is likely due to the use of customized gratings with very short periods of K = 120-180 mm and an operating wavelength of 850 nm.…”
Section: Discussionsupporting
confidence: 64%
See 1 more Smart Citation
“…Recently, Peshko et al have described the use of commercial PDMS to coat an LPG for the detection of toluene. 15 Despite the fact that the PDMS coating was not doped and therefore its refractive index was likely lower than 1.42, toluene could be detected at levels comparable to those in our study (100 ppm). The high sensitivity achieved in this case is likely due to the use of customized gratings with very short periods of K = 120-180 mm and an operating wavelength of 850 nm.…”
Section: Discussionsupporting
confidence: 64%
“…Peshko et al have recently reported the use of commercial polydimethylsiloxane (PDMS) to coat LPGs for the detection of toluene. 15 PDMS is a popular phase for SPME and shows excellent compatibility with optical fibre materials. A detection limit of 100 ppm of toluene in water was realized using customfabricated LPGs, with a comparably short pitch of 120 to 180 mm.…”
Section: Introductionmentioning
confidence: 99%
“…The general view of the mode envelope and exact spectral positions of the mode lines depend on the parameters of the fiber and the LPG. LPGs have applications like strain, bend, temperature, and refractive index change sensors [6][7][8]; light diffusers for medical applications [9]; and chemical sensors [10,11]. Hence, a fiber with an LPG may be used to monitor a patient's temperature and pulse, and could potentially be used to analyze the patient's blood chemical content levels.…”
Section: Introductionmentioning
confidence: 99%
“…Here, we are particularly interested in chemical sensor applications [2], more specifically in refractive index measurements of aqueous solutions. The use of a matched pair of LPG defining an in-line modal interferometer with a coaxial-Mach-Zehnder configuration has been investigated [3] for temperature and strain measurements [4] as well as for chemical applications [5]; this interferometric structure exhibits an enhanced sensitivity to the physical and chemical properties of the surrounding media.…”
Section: Introductionmentioning
confidence: 99%