1984
DOI: 10.1680/iicep.1984.1258
|View full text |Cite
|
Sign up to set email alerts
|

Lok-Test and Capo-Test Development and Their Applications.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
16
0

Year Published

1985
1985
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 11 publications
(16 citation statements)
references
References 0 publications
0
16
0
Order By: Relevance
“…The perfect locking of the B15G insert is due to the 30 Nm torque that makes the split sleeve to expand before pulling out the insert; -all the curves have similar shapes and are less dispersed in the case of transversal compression; -the good repeatability of the test, which is one of the basic requirements for an experimental technique; -the load-displacement curves of Fig. 26 resemble those of the LOK test [16]. In the first case, a = 0.32 is a value that can be derived also from the geometry of the expanded sleeve, while c = 3 has no direct For the case of transversal traction, the model parameters need to be changed to reasonably fit the test data, which is somehow an undesirable feature of a theoretical model.…”
Section: Calibration Of the B15g Insert: Test Resultsmentioning
confidence: 99%
See 3 more Smart Citations
“…The perfect locking of the B15G insert is due to the 30 Nm torque that makes the split sleeve to expand before pulling out the insert; -all the curves have similar shapes and are less dispersed in the case of transversal compression; -the good repeatability of the test, which is one of the basic requirements for an experimental technique; -the load-displacement curves of Fig. 26 resemble those of the LOK test [16]. In the first case, a = 0.32 is a value that can be derived also from the geometry of the expanded sleeve, while c = 3 has no direct For the case of transversal traction, the model parameters need to be changed to reasonably fit the test data, which is somehow an undesirable feature of a theoretical model.…”
Section: Calibration Of the B15g Insert: Test Resultsmentioning
confidence: 99%
“…of Civil, Chemical and Environmental Engineering of the University of Genoa -Italy, who fully funded the research program. (Bortolotti [37]) and with the LOK-CAPO test [16].…”
Section: Acknowledgmentsmentioning
confidence: 99%
See 2 more Smart Citations
“…Part of the field testing program involved attempts to measure the in situ compressive strength of the shotcrete using the Lok test and Capo test pullout tests (Petersen 1984) as described for concrete in ASTM C900.…”
Section: Lok Tests and Capo Testsmentioning
confidence: 99%