Local gas hydrodynamics in an external-loop airlift reactor: newtonian and non-newtonian fluids

Abstract: Measurements of local gas phase characteristics are obtained in an external-loop airlift reactor ®lled with newtonian or viscous non-newtonian liquids. A doubleoptical ®ber probe technique is used. It allows the determination of the axial and radial pro®les of gas hold-up, bubbling frequency, bubble size and velocity. In the case of air-water system, the results show a strong effect of radial liquid velocity variation on the gas¯ow characteristics at the bottom of the riser. In the case of highly viscous nonne… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0
1

Year Published

2003
2003
2013
2013

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(3 citation statements)
references
References 11 publications
0
2
0
1
Order By: Relevance
“…Fan et al [8] examined the hydrodynamic behavior of an annular three-phase fluidized bed and pointed out that the addition of a concentrically located inner column promoted bubble coalescence. Bentifraouine et al [9] measured the local gas-phase characteristics in an ELALR filled with Newtonian or viscous nonNewtonian liquids.…”
Section: Introductionmentioning
confidence: 99%
“…Fan et al [8] examined the hydrodynamic behavior of an annular three-phase fluidized bed and pointed out that the addition of a concentrically located inner column promoted bubble coalescence. Bentifraouine et al [9] measured the local gas-phase characteristics in an ELALR filled with Newtonian or viscous nonNewtonian liquids.…”
Section: Introductionmentioning
confidence: 99%
“…Blazej et al [5] studied the circulation velocity, overall riser and down comer gas holdup using three airlift reactors of different scale. Bentifraouine et al [7] studied the hydrodynamics of external loop airlift reactor using Newtonian and non-Newtonian liquids and they found that for highly viscous non-Newtonian solutions, the gas flow was strongly influenced by the gas distributor. Kilonzo et al [6] studied the influence of baffle clearance on the liquid circulation velocity, gas hold-up and pressure drop in a two riser rectangular airlift reactor with inverse internal loop and expanded gas-liquid separator using different concentrations of CMC solutions and developed gas holdup and liquid circulation velocity correlations using experimental data based on dimensional analysis.…”
mentioning
confidence: 99%
“…Осим тога реактори са механичким мешањем имају мању ефикасност (однос преноса масе и унете снаге у систем) у односу на АЛР [20]. Исто тако, у овом типу реактора није лако постићи услове високе стерилности, која је неопходна посебно код фармацеутских процеса, док је код АЛР то врло једноставно остварити услед непостојања покретних делова реактора [21].…”
Section: пнеуматски реактори са рециркулацијом -алр (Air-lift Reactors)unclassified