2006 International Conference on Power Electronic, Drives and Energy Systems 2006
DOI: 10.1109/pedes.2006.344238
|View full text |Cite
|
Sign up to set email alerts
|

Load Compensation for Diesel Generator Based Isolated Generation System Employing DSTATCOM

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
20
0

Year Published

2014
2014
2021
2021

Publication Types

Select...
6
1
1

Relationship

3
5

Authors

Journals

citations
Cited by 19 publications
(20 citation statements)
references
References 5 publications
0
20
0
Order By: Relevance
“…The mathematical model of the PV cell is illustrated in over-all diagram Figure 2. Based on circuit model, the current is transferred to load via controlled current source; it can be established in, Equation (7). It defines the current equation of single PV cell, the output of the PV cell resulting the physical attraction of the PV cell which is relating with , , and , from the irradiation and temperature over the other.…”
Section: Proposed Fundamental Frequency Based Id-iq Control Theorymentioning
confidence: 99%
See 1 more Smart Citation
“…The mathematical model of the PV cell is illustrated in over-all diagram Figure 2. Based on circuit model, the current is transferred to load via controlled current source; it can be established in, Equation (7). It defines the current equation of single PV cell, the output of the PV cell resulting the physical attraction of the PV cell which is relating with , , and , from the irradiation and temperature over the other.…”
Section: Proposed Fundamental Frequency Based Id-iq Control Theorymentioning
confidence: 99%
“…Such that harmonic distortions, unbalanced short-comings, active/reactive power exchanging are the major concerns which are easily transformed into equivalent resistive balanced system by using multi-functional DSTATCOM [6]. Effective control scheme generates the optimal switching signals, to achieve the definite compensation task which performs the proper functioning of the proposed MF-DSTATCOM [7], [8]. Various control schemes are reviewed by several literatures, such as symmetrical power theory [9], synchronous reference frame theory [10], instantaneous real power theory [11], etc.…”
Section: Introductionmentioning
confidence: 99%
“…Various practical applications of shunt compensating devices have been reported in the literature for removal of the DC component [5], selective harmonic compensation [6], voltage regulation [7], etc. Authors have described their worth in various applications, including in aircraft power systems [8], small hydro power generation [9], and diesel-engine-based power generation [10]. Performance of a shunt compensating device depends upon the type of control algorithm used for estimation of reference currents.…”
Section: Introductionmentioning
confidence: 99%
“…By replacing this with squirrel cage induction generator (SCIG) or by permanent magnet synchronous generator (PMSG) could be better alternative as they require less maintenance and no separate excitation control. To get best performance of DG set, the generator must operate close 80 to 100% of the full load [2][3].…”
Section: Introductionmentioning
confidence: 99%