Liquid sample introduction in inductively coupled plasma atomic emission and mass spectrometry — Critical review

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
24
0
1

Year Published

2015
2015
2021
2021

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 61 publications
(25 citation statements)
references
References 159 publications
0
24
0
1
Order By: Relevance
“…and, more importantly, to the strong counter-pressure at the tip of the nebulizer generated by the large difference of surface area between the entrance and the outlet of the nebulizer [26] (the nebulizer needle inner diameter goes from 5 mm to 0.3 mm). Moreover, the compressible gas partly absorbs the liquid pressure after the mass flow controller, reducing its volume, thus slowing the flow.…”
Section: Nebulizer Liquid Uptake Rate Versus Displacement Pump Gas Flmentioning
confidence: 99%
“…and, more importantly, to the strong counter-pressure at the tip of the nebulizer generated by the large difference of surface area between the entrance and the outlet of the nebulizer [26] (the nebulizer needle inner diameter goes from 5 mm to 0.3 mm). Moreover, the compressible gas partly absorbs the liquid pressure after the mass flow controller, reducing its volume, thus slowing the flow.…”
Section: Nebulizer Liquid Uptake Rate Versus Displacement Pump Gas Flmentioning
confidence: 99%
“…The sample volume is particularly critical for bio-molecules. Inkjet printing can be helpful in elemental analysis [ 33 , 34 , 35 , 36 ]. Thermal inkjet printing has been used in X-ray fluorescence analysis (XRF).…”
Section: Introductionmentioning
confidence: 99%
“…The micro deposits can also be used for calibration of TXRF devices with laser ablation combined with inductively coupled plasma mass spectrometry (ICP-MS) [ 33 , 44 ]. Cartridges and prototypes generating picoliter droplets are quite useful as aerosol generators in ICP-MS. Standard solutions can be sprayed with this aerosol generator directly into the ICP-MS, resulting in better sensitivities and lower detection limits [ 34 , 45 ].…”
Section: Introductionmentioning
confidence: 99%
“…There are many selection criteria for a specic spray chamber, such as inner volume, D 3,2 cutoff diameter, memory effect, signal stability and intensity, oxide ratios, detection limit, equilibration time, transport efficiency, matrix effects, .. [7][8][9] Many chamber geometries have been reported in the literature. 10 Double-pass spray chambers largely used in the past are today mainly replaced by single pass chambers or cyclones.…”
Section: Introductionmentioning
confidence: 99%