2018
DOI: 10.1016/j.bios.2018.09.019
|View full text |Cite
|
Sign up to set email alerts
|

Liquid gated ZnO nanorod FET sensor for ultrasensitive detection of Hepatitis B surface antigen with vertical electrode configuration

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
12
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 20 publications
(12 citation statements)
references
References 44 publications
0
12
0
Order By: Relevance
“…A comparison of this method with other methods developed for the detection of HBsAg is given in Table 1. These comparisons illustrate that the Au@UiO-66(NH 2 ) composite-based electrochemical sensor has several advantages, including a LOD and LDR for HBsAg when evaluated against most of the electrodes modified with different nanomaterials [37][38][39][40][41][42][43][44][45][46][47][48]. The previously reported sensors based on other nanomaterials showed good performance, but the better performance of the Au@UiO-66(NH 2 ) composite may be attributed to the large surface area of UiO-66(NH 2 ), high electrocatalytic activity of Au, and the fast electron transfer mediation from the immobilized HBsAg.…”
Section: Sensitivity Of the Developed Electrochemical Immunosensing Assay Against Hbvmentioning
confidence: 94%
“…A comparison of this method with other methods developed for the detection of HBsAg is given in Table 1. These comparisons illustrate that the Au@UiO-66(NH 2 ) composite-based electrochemical sensor has several advantages, including a LOD and LDR for HBsAg when evaluated against most of the electrodes modified with different nanomaterials [37][38][39][40][41][42][43][44][45][46][47][48]. The previously reported sensors based on other nanomaterials showed good performance, but the better performance of the Au@UiO-66(NH 2 ) composite may be attributed to the large surface area of UiO-66(NH 2 ), high electrocatalytic activity of Au, and the fast electron transfer mediation from the immobilized HBsAg.…”
Section: Sensitivity Of the Developed Electrochemical Immunosensing Assay Against Hbvmentioning
confidence: 94%
“…28 After that, ZnO nanorods were grown on the seeded area following a previously reported procedure. 15 Then, 50 mM zinc nitrate hexahydrate [Zn(NO 3 ) 2 •6H 2 O] was mixed in 50 mL of DI water and stirred for 10 min. After this, 50 mM hexamethylenetetramine (HMTA: C 6 H 12 N 4 ) was mixed with 50 mL of DI water, and this was also stirred for 10 min.…”
Section: ■ Materials and Methodsmentioning
confidence: 99%
“…Besides silicon, other materials have been explored in the development of FET immunosensors based on NWs, such as indium phosphide (InP) [55] and zinc oxide (ZnO) [129][130][131]. In the III-V semiconductor family, InP NWs exhibit exciting features for the development of FET-based immunosensors.…”
Section: Nanowires-silicon and Beyondmentioning
confidence: 99%
“…One of the distinctions of ZnO NRs is their use to build FET in a non-planar configuration. Chakraborty et al [130] showed the effect of the horizontal and vertical drain-source contact configuration in the sensitivity of a ZnO-NR-FET-based immunosensor for the ultrasensitive detection of Hep-B antigen biomarkers. First, the authors covalently immobilized the anti-Hep-B monoclonal antibodies on the ZnO NRs surface using the 3-mercaptopropyltrimethoxysilane (MTS).…”
Section: Nanowires-silicon and Beyondmentioning
confidence: 99%
See 1 more Smart Citation