2011
DOI: 10.1016/j.colsurfb.2011.07.052
|View full text |Cite
|
Sign up to set email alerts
|

Liquid crystal-based sensors for the detection of heavy metals using surface-immobilized urease

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
42
0

Year Published

2014
2014
2024
2024

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 81 publications
(43 citation statements)
references
References 22 publications
0
42
0
Order By: Relevance
“…It has been reported that metal ions affect orientations of LC under several possible mechanisms [9,[27][28][29]. To better understand this phenomenon, droplets of sodium chloride solution (0.5 M) were dispensed onto three types of surfaces.…”
Section: Effect Of Sodium Chloride On Orientations Of Lcsmentioning
confidence: 99%
See 1 more Smart Citation
“…It has been reported that metal ions affect orientations of LC under several possible mechanisms [9,[27][28][29]. To better understand this phenomenon, droplets of sodium chloride solution (0.5 M) were dispensed onto three types of surfaces.…”
Section: Effect Of Sodium Chloride On Orientations Of Lcsmentioning
confidence: 99%
“…For example, Abbott's group reported LC sensors for detecting peptides, lipids and other chemical compounds [2][3][4][5][6][7]. Other groups also developed a series of LC sensors for the detection of DNA, proteins and small molecules including thiol, amines and metal ions [8][9][10][11]. An interesting observation arising from these studies is that when a thin layer of LC is in contact with a liquid or a solid interface, the orientation of LC becomes very sensitive to ionic species (proton, electrolytes, and metal ions) present at the interface [12][13][14].…”
Section: Introductionmentioning
confidence: 97%
“…Helicobacter pylori (Hp) and Escherichia coli (E. coli) based on pH changes of the aqueous solution 41,42. In consideration of the sensitive pH responses of the fabricated Eu-POM/IL supramolecular spheres, we developed a simple and convenient approach with dual responses of turbidimetric and fluorescent signaling for the detection of urease.…”
mentioning
confidence: 99%
“…Gani et al (2010) developed PVCsolgel immobilized urease-based optical biosensor, but did not investigate lead effect. A liquid crystal (LC) based optical biosensor has also been reported by Hu and Jang (2011). The inadequacy with all these studies was the unaddressed issue of lead specificity and application on complex samples as milk.…”
Section: Introductionmentioning
confidence: 99%