2023
DOI: 10.1016/j.chroma.2023.463779
|View full text |Cite
|
Sign up to set email alerts
|

Liquid chromatography-mass spectrometry metabolite library for metabolomics: Evaluating column suitability using a scoring approach

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 31 publications
0
3
0
Order By: Relevance
“…Subsequently, other operations such as drying, redissolving and purifying the extract are carried out. Poor chromatographic performance and high ionisation efficiency are considered to be the reasons for the limitation of insufficient coverage of metabolomics and flawed system reproducibility 61,62 . Metabolites include small polar AAs to non‐polar lipids and the selection of chromatographic columns is closely related to the range of metabolites 63 .…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Subsequently, other operations such as drying, redissolving and purifying the extract are carried out. Poor chromatographic performance and high ionisation efficiency are considered to be the reasons for the limitation of insufficient coverage of metabolomics and flawed system reproducibility 61,62 . Metabolites include small polar AAs to non‐polar lipids and the selection of chromatographic columns is closely related to the range of metabolites 63 .…”
Section: Discussionmentioning
confidence: 99%
“…Poor chromatographic performance and high ionisation efficiency are considered to be the reasons for the limitation of insufficient coverage of metabolomics and flawed system reproducibility. 61,62 Metabolites include small polar AAs to nonpolar lipids and the selection of chromatographic columns is closely related to the range of metabolites. 63 Various other factors are involved in the metabolomics results, such as instrument parameter settings (separation parameters, ionisation source, data collection parameters, etc.…”
Section: Limitations and Future Research Directionsmentioning
confidence: 99%
“…Thus, a broad range of compounds can be covered by using both types. However, as several stationary HILIC and RP phases are available, their choice is crucial, which was already discussed extensively elsewhere (Diamantidou et al, 2023 ; Elmsjo et al, 2018 ; Si-Hung et al, 2017 ; Sonnenberg et al, 2019 ; Wernisch & Pennathur, 2016 ). Not only the different stationary phases but also the geometry and particle size of columns can affect the outcome of metabolomic studies.…”
Section: Introductionmentioning
confidence: 99%