2010
DOI: 10.3109/00365511003663630
|View full text |Cite
|
Sign up to set email alerts
|

Lipoprotein profile, plasma Ischemia Modified Albumin and LDL density change in the course of postprandial lipemia. Insights from the LIPGENE study

Abstract: Postprandial lipemia is associated with elevated risk of cardiovascular disease. Very little data exists regarding postprandial response in subjects with metabolic syndrome (MetS). The current study was conducted within the LIPGENE EU Integrated Project. Patients were randomized to one of the four isocaloric fatty meals (Oral Fat Tolerance Tests, OFTT): (A) high-fat, saturated fatty acid (SFA)-rich (HFSA), (B) high-fat, monounsaturated fatty acid (MUFA)-rich (HFMUFA), (C) low-fat, high-complex carbohydrate wit… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
18
0

Year Published

2012
2012
2020
2020

Publication Types

Select...
8

Relationship

4
4

Authors

Journals

citations
Cited by 13 publications
(19 citation statements)
references
References 37 publications
1
18
0
Order By: Relevance
“…Whilst an interaction was observed between change in LC n-3 PUFA and APOE genotype for TRL-C (following FA dietary intervention), significant differences between groups were not identified. Previous analysis of the LIPGENE data found a beneficial impact of dietary LC n-3 PUFA on LDL density 48 .…”
Section: Discussionmentioning
confidence: 90%
“…Whilst an interaction was observed between change in LC n-3 PUFA and APOE genotype for TRL-C (following FA dietary intervention), significant differences between groups were not identified. Previous analysis of the LIPGENE data found a beneficial impact of dietary LC n-3 PUFA on LDL density 48 .…”
Section: Discussionmentioning
confidence: 90%
“…OLTT was performed as described before . All patients were asked not to drink alcohol or drinks containing caffeine for 3 days before the test.…”
Section: Methodsmentioning
confidence: 99%
“…Nevertheless, the albumin concentration must be taken into account to correctly interpret cobalt binding results. Correction formulas to normalize IMA for high or low albumin concentrations have been proposed for use in human medicine, but the effects on test performance have been mixed . A prospective study, however, with samples collected specifically for %CB, rather than stored samples as used in this study, might allow discovery of a viable method to normalize %CB values for serum albumin concentrations.…”
Section: Discussionmentioning
confidence: 99%