Advances in Colloid Structures
DOI: 10.1007/bfb0114425
|View full text |Cite
|
Sign up to set email alerts
|

Lipid arrangements in human stratum corneum

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

5
26
0

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 17 publications
(31 citation statements)
references
References 15 publications
5
26
0
Order By: Relevance
“…This discussion is mainly based on data obtained from SAXS measurements on SC and SC lipid models that in fact, have shown somewhat contradictory results. In some of these studies, no swelling was detected in human and mouse SC [28,56,68], while minor swelling has been reported for the lipid bilayers in pig SC [27] and SC lipid models [69], and a rather pronounced swelling was shown for the short lamellar repeat distance structure in the SC of hairless mouse from 5.8 nm at 12 wt.% water to 6.6 nm at 50 wt.% water [57]. More recently, also neutron scattering results [70] indicated swelling of the bilayer regions of human SC.…”
Section: Solid and Fluid Sc Lipidsmentioning
confidence: 98%
See 1 more Smart Citation
“…This discussion is mainly based on data obtained from SAXS measurements on SC and SC lipid models that in fact, have shown somewhat contradictory results. In some of these studies, no swelling was detected in human and mouse SC [28,56,68], while minor swelling has been reported for the lipid bilayers in pig SC [27] and SC lipid models [69], and a rather pronounced swelling was shown for the short lamellar repeat distance structure in the SC of hairless mouse from 5.8 nm at 12 wt.% water to 6.6 nm at 50 wt.% water [57]. More recently, also neutron scattering results [70] indicated swelling of the bilayer regions of human SC.…”
Section: Solid and Fluid Sc Lipidsmentioning
confidence: 98%
“…134 Å and a short lamellar structure with a repeat period of ca. 60 Å [27,28]. The majority of the SC intercellular lipids are in a solid state at normal RH and ambient temperature [29][30][31][32][33][34].…”
Section: Introductionmentioning
confidence: 99%
“…The X-ray diffraction measurements were carried out at a Synchrotron Radiation Station (Daresbury, UK), equipped with a small-angle quadrant detector and a wide-angle INEL detector, in such a way that small-and wide-angle diffraction can be carried out simultaneously (Bouwstra et al, 1992a).…”
Section: Voltage Analysismentioning
confidence: 99%
“…The repeat distance (d) was calculated using the Bragg equation, stating the requirements for constructive interference: 2d.sinu 5 n.l (Bouwstra et al, 1992a).…”
Section: Voltage Analysismentioning
confidence: 99%
See 1 more Smart Citation