Linear Active Disturbance Rejection Control of Grid-Connected Photovoltaic Inverter Based on Deviation Control Principle

Abstract: Photovoltaic grid-connected power generation systems are easily affected by external factors, and their anti-interference performance is poor. For example, changes in illumination and fluctuations in the power grid affect the operation ability of the system. Linear active disturbance rejection control (LADRC) can extract the “summation disturbance” information from the system and eliminate the disturbance at the fastest speed by controlling the signal before it affects the final output of the system. In this p… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
4
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 11 publications
(5 citation statements)
references
References 25 publications
(37 reference statements)
0
4
0
Order By: Relevance
“…Theorem 1 (see [35]). Assuming that the lumped disturbance δ a is differentiable and bounded, considering the disturbance-observer (12), there exist the observer gains λ 1.a > 0, λ 2.a > 0, λ 3.a > 0, and 0 < b < 1, such that the observation error can be converged, that is, |x 3.a | ≤ ℓ a .…”
Section: Design Of the Dafsc Controllermentioning
confidence: 99%
See 1 more Smart Citation
“…Theorem 1 (see [35]). Assuming that the lumped disturbance δ a is differentiable and bounded, considering the disturbance-observer (12), there exist the observer gains λ 1.a > 0, λ 2.a > 0, λ 3.a > 0, and 0 < b < 1, such that the observation error can be converged, that is, |x 3.a | ≤ ℓ a .…”
Section: Design Of the Dafsc Controllermentioning
confidence: 99%
“…ere are many types of microgrid, which can be divided into island and grid connected according to whether it is interconnected with the public power grid; according to the current division, it can be divided into DC, AC, and AC\DC hybrid microgrid [9,10]. Because of regional reasons, some DER systems cannot interconnect with the enormous power grid [11,12], and then the DER system is operating in the island mode.…”
Section: Introductionmentioning
confidence: 99%
“…At this time, the adjustment can be realized by increasing the value of β , but this will have a great impact on the performance of ESO, which may cause ESO oscillation and even lead to system instability. 29 Therefore, it is not the best choice to adjust the derivative of z 2 and z 3 . Find an appropriate substitute to replace the deviation e ( t ) to adjust the derivative of z 2 and z 3 .…”
Section: Design Of Improved Adrcmentioning
confidence: 99%
“…In this context, and after proving the efficiency of the proposed technique, a modification is proposed to simplify the controller structure by replacing the nonlinear function with a simple error, as introduced in [25]. Indeed, the linearization of the ADRC has been proven to simplify the control loop structure and implementation in different application areas [26,27].…”