1997
DOI: 10.1016/s0021-9673(96)00782-0
|View full text |Cite
|
Sign up to set email alerts
|

Large-volume stacking for quantitative analysis of anions in capillary electrophoresis II. Large-volume stacking without polarity switching

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

2
51
0

Year Published

1998
1998
2013
2013

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 67 publications
(53 citation statements)
references
References 4 publications
2
51
0
Order By: Relevance
“…The effective reversion of the electroosmotic flow was controlled by injection of wat e r. Such a behav i o u r totally agreed with previously data of the literature [36,51].…”
Section: Capillary Coatingsupporting
confidence: 89%
See 2 more Smart Citations
“…The effective reversion of the electroosmotic flow was controlled by injection of wat e r. Such a behav i o u r totally agreed with previously data of the literature [36,51].…”
Section: Capillary Coatingsupporting
confidence: 89%
“…For instance OFM Anion -BT [16][17][18]32,35], cetyltrimethylammonium (CTAB) [21][22][23][24][25]36,37], hexamethonium [20,27,28,34] or trimethyltetradecylammonium (TTAB) [27,[29][30][31]33,[36][37][38] can be noted.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…This was originally developed by Burgi, who used diethylenetriamine (DETA) as an additive to reduce the EOF. 16 In previous LVSS reports, cationic-surfactants system [16][17][18][19][20][21][22][23][24][25][26][27] or a non-aqueous CE (NACE) mode [28][29][30][31][32] were mainly employed to obtain a slower anodic EOF. Despite that the first LVSS study 16 tried to inject a low-conductivity sample into the whole capillary to obtain a higher concentration efficiency, most LVSS studies have involved optimization of the injection length to be compatible with both the sensitivity and the resolution.…”
mentioning
confidence: 99%
“…Thus, stacking could be achieved at the boundary between sample and CE zone. The method has been confirmed on sensitivity improvement of CE analysis for environmental samples (Albert et al, 1997;Palmarsdottir et al, 1997;Liu et al, 2008), and received approval in trace determination of pesticides and other environmental pollutants (Nunez et al, 2002;Carabias-Martinez et al, 2003;Lagarrigue et al, 2008). Herein, we developed a method of CE which combined field-amplified sample stacking to analyze trace amount of Plt.…”
Section: Validity Of the Developed Methodsmentioning
confidence: 97%