2010
DOI: 10.1111/j.1464-410x.2010.09620.x
|View full text |Cite
|
Sign up to set email alerts
|

Laparoscopic high‐intensity focused ultrasound for renal tumours: a proof of concept study

Abstract: Study Type – Therapy (case series)
Level of Evidence What’s known on the subject? and What does the study add? Renal cancer is increasingly diagnosed when tumours are small and asymptomatic, during routine abdominal imaging. Whilst surgery is an effective and potentially curative option, it carries a significant risk of complications. Recent work suggests that thermally ablative therapies (RFA, cryotherapy, HIFU) may be suitable minimally invasive treatment options in selected patients. The success of extrac… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
22
0

Year Published

2013
2013
2019
2019

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 28 publications
(22 citation statements)
references
References 23 publications
0
22
0
Order By: Relevance
“…Prior studies have described the use of an 18-mm laparoscopic HIFU probe in animal models as well as in phase 1 clinical trials. [18][19][20][21] In our study, we present initial data on a novel, 12-mm, laparoscopic, HIFU probe for renal ablation. The new probe design incorporates high-resolution imaging, 2 confocal transducers for generation of the HIFU beam, a disposable probe tip with an integrated acoustic coupling sheath, and an active cooling water circuit to make the entire procedure efficient.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Prior studies have described the use of an 18-mm laparoscopic HIFU probe in animal models as well as in phase 1 clinical trials. [18][19][20][21] In our study, we present initial data on a novel, 12-mm, laparoscopic, HIFU probe for renal ablation. The new probe design incorporates high-resolution imaging, 2 confocal transducers for generation of the HIFU beam, a disposable probe tip with an integrated acoustic coupling sheath, and an active cooling water circuit to make the entire procedure efficient.…”
Section: Resultsmentioning
confidence: 99%
“…Previously studied HIFU probes required an 18-mm trocar in animal and human studies. [18][19][20][21] Orvieto et al 19 used an 18-mm laparoscopic HIFU probe in the porcine model to create lesions in 15 kidneys. Animals were euthanized either 4 days (acute group) or 14 days (subacute group) after the procedure.…”
Section: Commentmentioning
confidence: 99%
“…A recent study on the use of irreversible electroporation in 42 SRM indicated that at 3-year oncological outcomes may be unfavourable compared to other techniques [66]. Similarly, the treatment efficacy of both percutaneous and laparoscopic HIFU and the safety of the former in the treatment renal lesions have been questioned [67,68]. Overall, evidence is scarce and of low quality for newer energy sources.…”
Section: B Energy Sourcesmentioning
confidence: 99%
“…HIFU delivers ultrasonic energy to a focal area of tissue with resultant local heat and complete coagulative necrosis. [1][2][3][4] Transrectal HIFU has been proven to be capable of providing long-term local control of prostate cancer.…”
mentioning
confidence: 99%
“…HIFU delivers ultrasonic energy to a focal area of tissue with resultant local heat and complete coagulative necrosis. [1][2][3][4] Transrectal HIFU has been proven to be capable of providing long-term local control of prostate cancer. [5][6][7] A novel FDA (510k)-cleared laparoscopic HIFU probe for soft tissue ablation has been developed (Sonatherm laparoscopic probe; SonaCare Medical LLC, Indianapolis, IN, USA; Fig.…”
mentioning
confidence: 99%