2015
DOI: 10.1088/1748-0221/10/10/p10016
|View full text |Cite
|
Sign up to set email alerts
|

Laboratory tests of the Pulse Height Analysis system for Wendelstein 7-X

Abstract: A pulse height analysis (PHA) system has been designed and manufactured for the Wendelstein 7-X stellarator, in such a way as to be already compatible with later quasi-continuous operation requirements. The diagnostic will provide X-ray spectra with energy resolution better than 180 eV. The system has three energy channels: 0.25-20 keV, 0.95-20 keV and 1.5-20 keV. For each channel a separate Silicon Drift Detector (SDD) equipped with a suitably selected beryllium foil is used. The range of the 3 energy channel… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
16
0

Year Published

2016
2016
2018
2018

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 15 publications
(17 citation statements)
references
References 9 publications
0
16
0
Order By: Relevance
“…Impurity data analysis were performed using the measurements from the Pulse Height Analysis (PHA) system installed at W7-X [16][17][18][19][20]. The PHA diagnostic is designed to measure soft X-ray radiation in the energy range of 0.25 -20 keV.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Impurity data analysis were performed using the measurements from the Pulse Height Analysis (PHA) system installed at W7-X [16][17][18][19][20]. The PHA diagnostic is designed to measure soft X-ray radiation in the energy range of 0.25 -20 keV.…”
Section: Methodsmentioning
confidence: 99%
“…The PHA diagnostic is designed to measure soft X-ray radiation in the energy range of 0.25 -20 keV. This diagnostic is dedicated for delivering information about the impurities content in the plasma, Te and estimation of Zeff [16,21]. As presented in [19], the PHA diagnostic was commissioned during OP1.1 but only one energy channel of the PHA system has been optimized to deliver well-resolved spectra.…”
Section: Methodsmentioning
confidence: 99%
“…The resulting spectrum does not have an energy resolution high enough to reveal the line structure (as it is e.g. in the case of a PHA system [10]), but it gives the possibility of determining the slope of spectrum, which is directly related to the electron temperature of the plasma. Reconstruction of the energy spectra based on the experimental data can be realized by the deconvolution using e.g.…”
Section: Purpose Of the Mfs Systemmentioning
confidence: 99%
“…The Pulse Height Analysis (PHA) system 40,41 is used for investigation of soft X-ray emission in the energy range from 250 eV to 20 keV. It consists of 3 energy channels equipped with Silicon Drift Detectors (SDDs).…”
Section: Diagnostics For Core Impuritiesmentioning
confidence: 99%