2016
DOI: 10.1016/j.snb.2016.05.024
|View full text |Cite
|
Sign up to set email alerts
|

Label-free fluorescent assay for high sensitivity and selectivity detection of acid phosphatase and inhibitor screening

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
8
0

Year Published

2016
2016
2021
2021

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 31 publications
(8 citation statements)
references
References 35 publications
0
8
0
Order By: Relevance
“…To this end, some fluorescent chemosensors based on zinc complexes have been designed and used for ATP detection under biological pH conditions. However, the single recognition site in these fluorescent probes limits their selectivity to ATP compared with that of other phosphate anions. Taking advantage of the specific recognition, some aptamer-based fluorescence sensing assays have been developed for the selective detection of ATP. Nevertheless, the design and synthesization of a fluorescent probe for ATP sensing with high sensitivity and selectivity is still urgently required.…”
Section: Introductionmentioning
confidence: 99%
“…To this end, some fluorescent chemosensors based on zinc complexes have been designed and used for ATP detection under biological pH conditions. However, the single recognition site in these fluorescent probes limits their selectivity to ATP compared with that of other phosphate anions. Taking advantage of the specific recognition, some aptamer-based fluorescence sensing assays have been developed for the selective detection of ATP. Nevertheless, the design and synthesization of a fluorescent probe for ATP sensing with high sensitivity and selectivity is still urgently required.…”
Section: Introductionmentioning
confidence: 99%
“…Upon the preincubation of OPs with AChE, ATCh cannot be hydrolyzed into thiocholine because of the depressed AChE activity. Further, ATCh only has the thioether bond and quaternary ammonium salt group and consequently cannot wrest the CdS QDs from CdS/PPT/ITO via the formation of stronger chemical bonds. In this context, PEC current would not be decreased.…”
Section: Resultsmentioning
confidence: 99%
“…Through quantifying alcohols generated from ACP-catalyzed dephosphorylation of various orthophosphoric monoesters, several methods have been developed to probe ACP activity, including electrochemistry, , colorimetry, fluorimetry, potentiometric immunoassay, and chromatography . Among these methods, colorimetry, featuring simplicity, cost-effectiveness, rapidity, and visibility, has attracted extensive attention.…”
Section: Introductionmentioning
confidence: 99%