Label-Free cancer cell biosensor based on photonic crystal ring resonator

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 18 publications
(6 citation statements)
references
References 36 publications
0
6
0
Order By: Relevance
“…Note that the average refractive index of some normal cells in the near infrared regime are; cytoplasm (1.360–1.375), melanin (1.6–1.7), extracellular fluid (1.35–1.36), nucleus (1.38–1.41). In general, the refractive index of the cancer cells is higher than those of the normal cells due to more protein in their cytoplasm 67 . Thus, depending on the target cell, the refractive index variation range of the biosensor can be chosen and, apart from simulated values, other ranges are also considered in the literature in this regard (e.g., 1.392–1.401 in 68 and 1.41–1.58 in 69 ).…”
Section: Absorption Enhancement Using Epsilon-near-zero Cylindrical S...mentioning
confidence: 99%
“…Note that the average refractive index of some normal cells in the near infrared regime are; cytoplasm (1.360–1.375), melanin (1.6–1.7), extracellular fluid (1.35–1.36), nucleus (1.38–1.41). In general, the refractive index of the cancer cells is higher than those of the normal cells due to more protein in their cytoplasm 67 . Thus, depending on the target cell, the refractive index variation range of the biosensor can be chosen and, apart from simulated values, other ranges are also considered in the literature in this regard (e.g., 1.392–1.401 in 68 and 1.41–1.58 in 69 ).…”
Section: Absorption Enhancement Using Epsilon-near-zero Cylindrical S...mentioning
confidence: 99%
“…The results indicated that the sensor achieved a best sensitivity value of S = 20,393 nm/RIU and an FOM of 9104.017 ± 606.93 RIU −1 [ 187 ]. A recent study proposed the utilization of a RR in 2D PhC biosensors [ 188 ]. The biosensor configuration, as depicted in Figure 12 b, consists of an RR accompanied by two bus WGs.…”
Section: Si Photonics Sensorsmentioning
confidence: 99%
“…To form the resonator and WG, a row of rods was selectively removed from the structure. Specifically, the ring RR was composed of a large green dielectric rod encircled by four smaller rods, measuring 340 nm and 162 nm in radius, respectively [ 188 ]. The objective of this design was to enable the detection and differentiation of both normal and cancerous cells.…”
Section: Si Photonics Sensorsmentioning
confidence: 99%