2015
DOI: 10.1016/j.knee.2015.07.014
|View full text |Cite
|
Sign up to set email alerts
|

Kinematics of passive flexion following balanced and overstuffed fixed bearing unicondylar knee arthroplasty

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

4
11
0

Year Published

2016
2016
2018
2018

Publication Types

Select...
4
2

Relationship

4
2

Authors

Journals

citations
Cited by 10 publications
(15 citation statements)
references
References 18 publications
(27 reference statements)
4
11
0
Order By: Relevance
“…This finding agrees with our results: internal rotation of 14° in the intact knee from 0° to 90° of flexion. Our model predicted 11.2° of tibial external rotation from 0° to 30°of flexion after UKA implantation in a balanced position, which also agrees with a previous cadaveric study …”
Section: Discussionsupporting
confidence: 91%
See 2 more Smart Citations
“…This finding agrees with our results: internal rotation of 14° in the intact knee from 0° to 90° of flexion. Our model predicted 11.2° of tibial external rotation from 0° to 30°of flexion after UKA implantation in a balanced position, which also agrees with a previous cadaveric study …”
Section: Discussionsupporting
confidence: 91%
“…Similarly, the 2.8 mm RMS difference between predicted and experimentally measured AP translations of the lateral condyle was 2.2 times less than the predicted differences caused by installing the balanced UKA. The model of the intact knee also corroborated the AP condylar translations measured in a corresponding cadaver experiment, and, after UKA, the abnormal external rotation with passive flexion measured in a group of ten similarly tested knee specimens . Thus, the conclusions derived using the model are strong.…”
Section: Discussionsupporting
confidence: 72%
See 1 more Smart Citation
“…Moreover, the chosen thickness of the polyethylene bearing can have important implications on implant wear, alignment, knee kinematics, and ligament tensioning, among other factors, for both total and unicondylar knee arthroplasty [16,30,31]. To the authors' knowledge, there have been no previous studies documenting the impact of bearing thickness on BCR TKA kinematics.…”
Section: Discussionmentioning
confidence: 99%
“…Generally, ligament balance is subjectively assessed by the surgeon [13] and can be modified by altering the thickness of the polyethylene bearing. If chosen improperly by using either an under-or oversized polyethylene insert, the resulting tibiofemoral kinematics, contact pressure, and wear properties can be altered [14,15].While previous studies have documented the effect of bearing thickness on unicompartmental implants [16,17], there have been no studies documenting the influence on BCR TKA.…”
Section: Introductionmentioning
confidence: 99%